ROOM and SERVICE icons flash while the room temperature still shows on a Trane heat pump: The control shows the room reading but flags the remote indoor sensor.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: XR402 with remote indoor sensor

Common causes of room and service icons flash while the room temperature still shows

  • Installer step 36 selects a remote indoor sensor but none is connected.
  • A wire is broken or not connected.
  • The remote sensor has failed open.

How to fix room and service icons flash while the room temperature still shows: step by step

  1. Select the correct option for installer step 36.
  2. Repair the wire, connection or sensor.
  3. The control falls back to its on-board sensor if the remote sensor fails.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Trane Heat Pump codes

Source: Trane XR402 installer's guide 18-HD29D3-4, p. 14. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.