Trane Heat Pump: Outdoor temperature display is wrong
Outdoor temperature display is wrong on a Trane heat pump: The outdoor reading does not match a reference reading.
Applies to: XR402 with outdoor sensor
Common causes of outdoor temperature display is wrong
- Outdoor temperature display needs calibration.
How to fix outdoor temperature display is wrong: step by step
- Calibrate the outdoor sensor in user setup step 60.
- Disconnect the outdoor sensor from the control terminal block and measure the sensor and field wiring resistance; compare with Table 2.
If the unit shows an error code, look it up: Trane Heat Pump codes
Source: Trane XR402 installer's guide 18-HD29D3-4, p. 14. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.