Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Trane Heat Pump: Heat pump wiring notes (third-party condensate switch and X2 for defrost)

Updated · by Aurora Star Tech Inc.

Heat pump wiring notes (third-party condensate switch and X2 for defrost) on a Trane heat pump: Wiring notes that apply to the heat pump wiring diagrams on pages 5 to 7.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Heat pump systems with XR103 thermostat

How to fix heat pump wiring notes (third-party condensate switch and x2 for defrost): step by step

  1. Wire any third-party condensate overflow switch in series between thermostat Y and the airflow control board Y1.
  2. Run X2 to energize auxiliary heat during defrost.
  3. Use the diagram that matches the indoor unit and outdoor unit, such as TAM series, S9V2 furnace, variable speed gas furnace, GAT2/GAM2/TEM3/TEM4 or GAM5A/TAM4/GAF2-36M.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Trane Heat Pump codes

Source: Trane XR103 installation and user guide 18-HD55D1-1C-EN, p. 5-7. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977