Trane Heat Pump: Auxiliary heat lockout by outdoor temperature
Auxiliary heat lockout by outdoor temperature on a Trane heat pump: Auxiliary heat lockout is set with an outdoor temperature. No installed auxiliary heat stage turns on during heating above that temperature. During defrost this setting is ignored and the Defrost Heater Balance Point thresholds are used instead. Requires the outdoor sensor.
Applies to: Heat pump with auxiliary heat and TCONT402AN32DA
How to fix auxiliary heat lockout by outdoor temperature: step by step
- Confirm the outdoor sensor is installed and enabled.
- Set the auxiliary heat lockout outdoor temperature in the installer setup.
- Check that no auxiliary heat stage runs above the set temperature during heating.
If the unit shows an error code, look it up: Trane Heat Pump codes
Source: 18-HD29D3-4 installer's guide, p. 17. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.