Trane General: Heat, cool or fan runs constantly
Heat, cool or fan runs constantly on a Trane general: System runs with no call for heat, cool or fan.
Applies to: TCONT302 / TCONT303
Common causes of heat, cool or fan runs constantly
- Short in wiring
- Short in thermostat
- Short in heat/cool/fan system
- FAN switch set to ON
How to fix heat, cool or fan runs constantly: step by step
- Check each wire so none are shorted or touching.
- Make sure no bare wire sticks out from the terminal block.
- Reset the thermostat and retest.
- If the fault remains, have the system tested by the manufacturer or service person.
- If the system tests good, replace the thermostat.
If the unit shows an error code, look it up: Trane General codes
Source: Trane XR302/XR303 installation and user guide, p. 24. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.