Activate heating set back (FP, 46°F / 8°C)

Viessmann · HEAT mode only

Heating-only function that holds a 46°F (8°C) set point while in HEAT mode. Unit runs high fan until space reaches 46°F. Indoor display shows FP. Cancelled by ON/OFF, SLEEP, MODE, FAN or either TEMP arrow.

  1. Set the unit to HEAT mode with the remote pointed at the indoor unit.
  2. Press the down arrow until the set point is 60°F (16°C).
  3. Press the down arrow two times within two seconds.

Combined Timer ON and Timer OFF program

Viessmann · All models

Use both timers to set a start and stop time. Order of setting depends on whether the unit is on or off.

  1. If the unit is off: set TIMER ON, then TIMER OFF. It starts at ON time and stops at OFF time.
  2. If the unit is on: set TIMER OFF first, then TIMER ON. It stops at OFF time and starts again at ON time.

Enter and cancel special functions with SET

Viessmann · Wireless remote

Functions include Breeze Away, Active Clean, FRESH, SLEEP and FOLLOW ME. The same steps cancel a selected function.

  1. Press SET to enter the FUNCTION setting.
  2. Press SET, or TEMP up/down, to scroll to the desired function.
  3. When the symbol flashes, press OK to confirm.
  4. To cancel, repeat the same steps.

Fan speed is locked in AUTO and DRY

Viessmann · Wireless remote control

The remote sets fan speed automatically in AUTO and DRY modes, so manual fan speed cannot be selected there.

  1. Select COOL or HEAT if manual fan speed is needed.
  2. Use FAN or fan speed buttons in those modes.

Louver direction and auto swing

Viessmann · Vitocal IND-F floor console, Size 12 (12XAK)

Up-down louver positions are stored, but are cancelled by TURBO, MANUAL, or a power interruption.

  1. Press DIRECT repeatedly to step through up-down positions. Each press moves the louver 30 degrees.
  2. Use the downward or horizontal position for cooling, and the vertical position for heating.
  3. Press SWING to start or stop automatic swing.
  4. Always adjust with the remote, not by hand.
  5. If the louver was moved by hand out of its range, switch the unit off, then back on.

Set cooling and heating temperature compensation

Viessmann · DLCURA 18-60 indoor/outdoor units

Two compensation values are set the same way. The display shows Ch during the query.

  1. Press On/Off for 2 seconds to enter the compensation settings.
  2. Press OK to send the query code (display shows Ch).
  3. Use Up/Down to select the compensation value, then press OK.
  4. Press On/Off for 2 seconds to exit.

Set cooling frequency threshold

Viessmann · DLCURA 18-60 indoor/outdoor units

Adjust the cooling frequency threshold. Must be done within 1 minute after power on.

  1. Within 1 minute of power on, press On/Off for 2 seconds to enter Cooling Frequency Threshold Settings.
  2. Use Up/Down to select the threshold, then press OK.
  3. Press On/Off for 2 seconds to exit.

Set heating frequency threshold

Viessmann · DLCURA 18-60 indoor/outdoor units

Adjust the heating frequency threshold. Must be done within 1 minute after power on.

  1. Within 1 minute of power on, press On/Off for 2 seconds to enter Heating Frequency Threshold Settings.
  2. Use Up/Down to select the threshold, then press OK.
  3. Press On/Off for 2 seconds to exit.

Set the room temperature set point

Viessmann · All models

Set point is adjusted in 1°F or 1°C steps. Page 9 gives the range as 62°F (17°C) to 86°F (30°C); page 8 gives a model-dependent range. In COOL the unit will not start if the set point is above room temperature; in HEAT it will not start if the set point is below room temperature.

  1. Press TEMP up or down to change the set point.
  2. Wait for the beep and confirm the new value on the display.
  3. If the unit does not start, check that the set point is on the correct side of room temperature for the mode.

SILENCE function

Viessmann · Remote controller

Press SILENCE on the remote to start. The compressor runs below F2 and the indoor unit gives a faint breeze to reduce noise.

  1. Press SILENCE on the remote controller to turn the function on.

Timer function options

Viessmann · Remote control timer

24-hour timing range. Options: TIMER ON, TIMER OFF, TIMER ON/OFF and TIMER OFF/ON. Timer does not change the current operating mode, and the setting time is relative. The timer exits if the unit has a malfunction.

Timer OFF (stop time) setting

Viessmann · All models

Same stepping as Timer ON (30 min to 10 h, then 60 min to 24 h). The unit shuts off automatically at the set time.

  1. Press TIMER OFF to start the time sequence.
  2. Press again to step the time up.
  3. Set to 0.0 to cancel.

Timer ON (start time) setting

Viessmann · All models

Can be set with the unit on or off. Each press adds 30 minutes up to 10 h, then 60 minute steps up to 24 h. The TIMER light on the unit lights when set.

  1. Press TIMER ON to start the time sequence.
  2. Press again to step the time up.
  3. Set to 0.0 to cancel.

Timer ON and TIMER OFF

Viessmann · Vitocal IND-F floor console, Size 12 (12XAK)

Each press adds time. TIMER ON and TIMER OFF can be used alone or together. Setting either to 0.0 cancels it.

  1. Press TIMER ON to set the auto-start time. Each press adds 30 minutes up to 10 h, then 60 minutes up to 24 h.
  2. Press TIMER OFF to set the auto-stop time, using the same increments.
  3. To cancel, set the timer back to 0.0.

Turn off indoor display and buzzer

Viessmann · Wireless remote control

The LED button turns the indoor unit display and buzzer on or off for a quieter room.

  1. Press the LED button on the remote to toggle the indoor display and buzzer.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.