Service & test modes: Mini-Split tips (part 2 of 2)

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on service & test modes for mini-split. Check each one against the manual for your exact model before acting.

Open the wired controller setup menu

Viessmann · Wired controller KSACN0701AAA

Entering the SP/AF menu requires the system to be off. Only SP and AF are needed for airflow setup; the thermistor sub-menus are not for this task.

  1. With the system off, press and hold COPY for about 4 seconds.
  2. Use + or - to move between menu entries.
  3. Choose SP or AF only. Leave T1, T2, T2b, T3 and T4 alone.

Point check (information enquiry)

Viessmann · Indoor unit display and remote control

Press LED DISPLAY or AIR DIRECTION to step through the next item. Each item name shows for about 2 seconds, then its value shows for 25 seconds. Use the enquiry tables for names and value decoding.

  1. Press LED DISPLAY or AIR DIRECTION to enter information enquiry.
  2. Press again to move to the next item.
  3. Read the code name for about 2 seconds, then the value for about 25 seconds.
  4. Decode the value with the point check table.

Read live data with the outdoor check button (SW1)

Viessmann · DLCMRBH / DLCMHBH multi-zone outdoor units 18-48K (Midea, Carrier, Viessmann Vitocal 200-S)

Each press of SW1 steps through a value on the outdoor display.

  1. Press 1 = number of indoor units talking. 2 = mode (0 off, 1 fan, 2 cool, 3 heat, 4 forced cool, A forced defrost).
  2. Presses 17-21 = T2B per zone, 22-26 = room temp per zone, 27-31 = coil temp per zone, 32 = T3, 33 = T4, 34 = discharge temp.
  3. Press 45 (all sizes) = last fault or protection (00 = none). See the check switch table for the full list; the 18K board uses a slightly different order.

Run a test with the indoor unit MANUAL button

Viessmann · Indoor unit

Use the MANUAL button on the indoor unit to run a test without the remote control.

  1. Open the front panel of the indoor unit.
  2. Push MANUAL once to energise the unit. Preset is 76°F (24°C), fan AUTO, and discharge direction preset for the current cool or heat mode.
  3. Push MANUAL twice more to turn manual operation off after the test.

Run the automatic wiring / piping correction

Viessmann · DLCMRBH / DLCMHBH multi-zone outdoor units 18-48K (Midea, Carrier, Viessmann Vitocal 200-S)

The outdoor unit can find and fix crossed wiring vs piping ports by itself.

  1. Outdoor temperature must be above 41 F (5 C). Indoor units do not need to be running.
  2. Hold CHECK (SW1) on the outdoor board about 6 seconds until CE shows (FA may show first, keep holding).
  3. Indoor units go to 76 and the compressor runs for about 5-10 minutes.
  4. When CE changes to 00 it is done. Set each indoor unit back with its remote (they stay at 76).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.