Restart the gateway (Reset button)

Bosch · IDS Premium Connected gateway

The Reset button powers the gateway off and back on.

  1. Press the Reset button once

Restore system defaults from the outdoor board (0C)

Gree · Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V..WL/C-T(U))

Three variants clear different amounts; 0C blinks 3, 5 or 7 seconds on the master board to show which one is running.

  1. Full clear: hold SW1 and SW4 for over 10 seconds (0C blinks 3 s).
  2. Clear that keeps quantities and commissioning status: hold SW2 and SW4 for over 10 seconds (0C blinks 5 s).
  3. Third variant (manual prints SW3 and SW4): hold for over 10 seconds (0C blinks 7 s).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.