Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Reset & cancel: General tips

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on reset & cancel for general. Check each one against the manual for your exact model before acting.

Do not stop STR mode manually

Navien · WEC600

Stopping STR by hand leaves the sterilization incomplete. If it is stopped, the STR mode has to be restarted and completed.

  1. Let STR run to completion without interrupting it.
  2. If it was stopped manually, restart STR and let it finish.

Factory reset and install test mode

Navien · WEC600

Deletes all saved data and returns the unit to factory defaults. The unit then enters install test mode. Shows FCt on the display.

  1. With the panel off and NDI modules stopped, press and hold Back.
  2. While holding Back, press OK three times quickly.
  3. Confirm FCt is shown on the display.

Factory reset with the main panel off

Navien · WEC600

This mode works only when the main panel is off and the NDI module performance has stopped. It resets to factory defaults and deletes all saved data.

  1. With the main panel off, hold Back for more than 3 seconds while pressing Power briefly 3 times.
  2. Set the time again after reset.

Forced CIP after STR

Navien · WEC600

Forced CIP (option 08 of section 3.8) should not be used right after STR, because CIP is reset when STR finishes.

  1. Wait until the STR mode has finished before running Forced CIP.
  2. Do not add detergent, including chlorine tablets, into the CIP tank.

Powering the WEC off correctly

Navien · WEC600

Always shut the unit down from the main panel. Pulling the plug is not the correct shutdown. If the unit is only switched off at the panel and stays plugged in, it still flushes the NDI modules about every 24 hours after last use. When it sits unused for a long time, it may also regenerate periodically to protect the system.

  1. Press and hold the [Power] button on the main panel for more than 3 seconds to turn the unit off.
  2. Do not unplug the power cord to turn the unit off.
  3. Before any repair, inspection or part replacement, unplug the power plug.

Powering the WEC on

Navien · WEC600

The unit is started from the main panel, not by plugging it in.

  1. Press and hold the [Power] button on the main panel for more than 3 seconds.

Acknowledge a fault

Viessmann · Vitotrol 300A

Acknowledge the fault by following the instructions on the display.

  1. Follow the on-screen instructions to acknowledge the fault.

Activate Configuration saves and reboots

Viessmann · Versatronik 535 Solar gateway

Changes do not take effect until Activate Configuration is confirmed. Choosing SAVE at that prompt stores the settings and reboots the gateway. The Restore Defaults and Change Password screens are basic.

  1. Press SAVE on every configuration screen where a change is made.
  2. Confirm Activate Configuration and select SAVE to apply and reboot.

Reset to factory settings

Viessmann · Vitoconnect OPTO2

Resets all changed values to their factory settings.

  1. Press the Reset button for at least 30 seconds until the LED flashes red.
  2. Press the Reset button again within 5 seconds.
  3. Confirm the LED is off; the Vitoconnect restarts.

Reset Vitoconnect to factory settings

Viessmann · Vitoconnect OPTO2

Resets all changed values back to factory settings.

  1. Press the Reset button for at least 30 seconds until the LED flashes red.
  2. Press the Reset button once more within 5 seconds.
  3. Wait until the LED goes out. The Vitoconnect restarts.

Restart the Vitoconnect

Viessmann · Vitoconnect OPTO2

Restart after a fault has been fixed.

  1. Press the Reset button and the operating button together for about 15 seconds.
  2. Wait for the green LED (start-up can take up to 2 minutes).
  3. Wait for the white LED, which means the Vitoconnect is ready.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977