Short, practical technician tips on reset & cancel for boiler. Check each one against the manual for your exact model before acting.

Resetting stored data

Viessmann · Vitocrossal 300 CU3A with Vitotronic 200 KW6B

You can reset burner hours run, fuel consumption, and (with solar) solar yield, solar pump hours and output 22 hours, or all of them together.

  1. Open the extended menu.
  2. Choose Information.
  3. Choose Reset data.
  4. Select the data to reset.

Resetting the maintenance display

Viessmann · Vitodens 100-W

Clears the service message after maintenance has been done.

  1. Open the service menu with the button combination.
  2. Select Reset service messages and press OK.

Restart or reset the controller

Viessmann · Versatronik COMO OT

A restart and a reset to default values are done with the reset button using a pointed tool. Reset to defaults keeps the heating programs and hot water program.

  1. To restart, press the reset button with a straightened paper clip.
  2. To load default settings, press Prog and Reset together, release Reset, and keep Prog held until EEPROM appears.
  3. Re-enter any values that were changed by the reset.

Restart the controller after a fault

Viessmann · Versatronik 200 controller

The system must be restarted after a fault is fixed. A RESET is a brief shutdown of the controller, which restarts and keeps the values already set.

  1. Remedy the fault.
  2. Switch the controller off briefly at the mains switch.
  3. Check that the controller restarts and runs with its stored values.
  4. If needed, reset the User, Expert or Time program values separately in the Service level.

Restart the start-up wizard

Viessmann · Vitocrossal 300 CU3A

Use after an entry error or after adding system components. Some settings may reset, so record them first.

  1. Record current settings.
  2. Press OK and menu together for about 4 seconds.
  3. Select Service Functions.
  4. Select Set-up Wizard.
  5. Select Yes.
  6. Press OK to restart the wizard.

Restore factory settings for a heating circuit

Viessmann · Vitocrossal 300 CA3B with Vitotronic 300 GW6C

Resets the values for one heating circuit to factory settings. Heating circuit names stay. The reset must also be done on the main user interface and on all service displays.

  1. From the home screen, open Menu, then Settings.
  2. Open Factory settings.
  3. Select heating circuit 1, 2 or 3.
  4. Tap OK to confirm.

Restore factory settings for one heating circuit

Viessmann · Vitotronic 300-K, MW2C

Factory settings can be restored one heating circuit at a time. This resets the set room temperatures, operating program, DHW setpoint, all time programs, heating curve slope and shift, and the comfort and energy saving functions. A custom circuit name is kept.

  1. From the home screen, open 'Settings' and select 'Factory settings'.
  2. Select the required heating circuit.
  3. Confirm to restore, or cancel to keep the current values.

Restore factory settings per heating circuit

Viessmann · Vitocrossal 300 CU3A

Resets all changed values for one heating circuit at a time. Heating circuit names are not reset.

  1. Open the extended menu.
  2. Select 'Settings'.
  3. Select 'Standard setting'.
  4. Choose 'Heating circuit 1', 'Heating circuit 2' or 'Heating circuit 3'.

Restore identical time phases for all days

Viessmann · Vitocontrol-S, VD2/CT3/CM2

If different phases were set for individual days, you can reset all days to one common schedule. This also resets all time phases to factory settings.

  1. In the central heating time program, press up/down until 1-7 shows.
  2. Confirm to apply the same time phases to all days.
  3. Note that all time phases return to factory settings.

Restoring factory settings

Viessmann · Vitotrol 300A remote control

Factory settings can be restored for each heating circuit separately. Resets set room temperature, set DHW temperature, time programs for central heating, DHW and DHW recirculation pump, and ends party mode, economy mode and holiday program.

  1. Open the extended menu.
  2. Select Settings, then Standard setting.
  3. Select Heating circuit 1, 2 or 3.

Restoring factory settings for a heating circuit

Viessmann · Vitocrossal 300 CA3B

Restores the values of one heating circuit to factory settings. Heating circuit names are kept. The reset must be done on the main user interface and on all service displays.

  1. From the home screen, select Settings.
  2. Select Factory settings.
  3. Select Heating circuit 1, 2 or 3.
  4. Confirm.

Restoring factory settings per heating circuit

Viessmann · Vitocrossal 300 CA3B Dual Fuel Series 2.5 to 6.0

Each heating circuit's modified values can be reset individually. Assigned heating circuit names are kept.

  1. Go to Menu > Settings > Factory settings.
  2. Select Heating circuit 1, 2 or 3.
  3. Press OK to confirm.
  4. This must be done on the main interface and on all service displays.

Return to main view

Viessmann · Vitotron 100 VLN2 control panel

The panel goes back to the main view by itself after one minute with no button presses.

  1. Press the power button 9 to return to the main view immediately.
  2. Wait one minute with no button presses to return automatically.

Return to standard menu

Viessmann · Menu navigation

The display reverts to the standard menu automatically 2 minutes after the last setting change.

  1. Wait 2 minutes after the last change for automatic return to the standard menu.
  2. If the screen saver is on, press any key except the one marked '?'.
  3. If elsewhere in the menu, keep pressing the back key until the standard menu appears.

Screen saver and power failure behavior

Viessmann · Vitotronic 200 KW6B programming unit

The screen saver turns on after a few minutes without key presses and dims the display. All settings are kept during a power failure. After a long power-off, the date and time must be reset.

  1. Press OK to wake the screen and return to the standard menu.
  2. After a prolonged power-off, reset the date and time (see operating instructions, p. 30).

Service message display and reset

Viessmann · Vitodens 200-W B2HB

The Service display with a wrench symbol appears when the limits in coding 21 and 23 are reached. The red fault light flashes.

  1. Press OK to acknowledge the service message.
  2. If not reset, the message returns on the following Monday.
  3. After service is done, press OK and the scroll key together for about 4 seconds.
  4. Select Service functions, then Service reset.
  5. Hours run and time interval restart at 0.

Stop central heating

Viessmann · Vitotronic 300-K

Two options stop central heating while keeping other functions. Choose summer mode to keep DHW, or standby to keep only frost protection.

  1. Open the extended menu.
  2. Select the heating circuit if needed.
  3. Select Heating, then Heating program.
  4. Select Only DHW for summer mode, or Standby mode for frost protection monitoring.

Stop DHW and room heating

Viessmann · Vitotronic 300-K, MW1B

Turns off both DHW heating and room heating, leaving only frost protection monitoring active.

  1. Open the extended menu.
  2. Select the heating circuit if needed.
  3. Select "Heating".
  4. Select "Heating program".
  5. Choose "Standby mode" (frost protection monitoring).

Stop DHW heating

Viessmann · Vitotronic 300-K

Used when neither DHW nor central heating is wanted. Standby mode keeps only frost protection active.

  1. Open the extended menu.
  2. Select the heating circuit if needed.
  3. Select Heating, then Heating program.
  4. Select Standby mode (frost protection monitoring).

Stop or prevent DHW heating

Viessmann · DHW tank

Lowering the DHW temperature setpoint to 50°F (10°C) stops DHW heating during standard operation.

  1. Press Menu, then DHW, then DHW temperature.
  2. Set the value to 50°F (10°C).
  3. Press OK to confirm.

System shutdown

Viessmann · Vitocrossal 300 CA3B Dual Fuel

Shut the system down by switching off the main power and all related switches, then closing the system valves. Refer to the system control documentation for other controls.

  1. Turn off the main power switch.
  2. Turn off all additional switches for pumps or controls, including the burner main switch.
  3. Close all valves in the system.

Turn off comfort mode

Viessmann · Vitocrossal 300 CA3B with Vitotronic 300 GW6C

Ends comfort mode manually. It also ends on its own when the system switches to standard heating mode under the time program, or after 8 hours. Contact the heating contractor if you want to change the automatic end.

  1. From the home screen, open Menu, then Heating.
  2. Select the heating circuit.
  3. Open Comfort mode and select Comfort mode again so the white frame resets.
  4. Press OK to confirm.

Turn off economy mode

Viessmann · Vitocrossal 300 CA3B with Vitotronic 300 GW6C

Ends economy mode manually. It also ends automatically when the time program switches the system to reduced heating mode.

  1. From the home screen, open Menu, then Heating.
  2. Select the heating circuit.
  3. Open Economy mode and select Economy mode again so the white frame resets.
  4. Press OK to confirm.

Turn off gas to the boiler

Viessmann · B1HE and B1KE Combi boilers

Use this shutdown sequence when the boiler is to be serviced or left off.

  1. Set the thermostat or control to lowest setting.
  2. Turn off all electric power to the boiler if service is to be performed.
  3. Turn off the control gas switch.

Undo a premature service reset

Viessmann · Vitocrossal 300 CA3B

If service was reset early, the counters can be restarted with the service coding.

  1. Set coding 24 in the Boiler group from 24:1 back to 24:0.
  2. This restarts the hours-run and time interval counters at 0.

Viewing and acknowledging fault messages

Viessmann · Vitotronic 300-K MW2C

Red fault indicator flashes on the control enclosure when a fault is present. Acknowledging silences any alarm equipment.

  1. Tap the fault symbol in the footer to open the list.
  2. Tap ? to see information and self-help tips for the fault.
  3. Note the fault code and cause, for example f0 Combustion controller.
  4. Tap Acknowledge.
  5. Notify the heating contractor.
  6. If several service messages are active, tap Faults to show the fault list.

Wake the display and cancel a setting

Viessmann · Vitotronic 300-K MW1B

After a few minutes without input the screen saver starts and display brightness drops. The back key cancels a setting that has been started and takes you to the previous menu step. Holding a key down ends a multi-step entry early.

  1. From the screen saver, press OK to wake the display.
  2. Press the back key to cancel an unfinished setting.
  3. If you want to end a time phase entry early, keep pressing back until the wanted screen appears.

Wake the screen saver

Viessmann · Vitotronic 300-K (type MW2B)

The screen saver starts after a few minutes without changes on the programming unit and the display brightness is reduced.

  1. Press OK to return to the standard menu from the screen saver.
  2. To open the extended menu from the screen saver, press OK and then the extended menu key.

When comfort mode ends

Viessmann · Vitocrossal 300 CA3B Series 2.5 to 6.0

Comfort mode ends automatically when the system switches to standard heating mode under the time program, or after 8 hours. Contact your heating contractor if you want to change this.

Blocked combustion air or vent lockout

Weil-McLain · All listed boiler series

The boiler shuts down automatically when combustion air or the vent is blocked and shows a manual reset lockout.

  1. Remove any easily accessible blockage in the combustion air or vent.
  2. On the control display, select <Reset Lockout>.
  3. If the blockage cannot be removed, have a qualified service technician check the system.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.