Other: Mini-Split tips (part 8 of 8)

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on other for mini-split. Check each one against the manual for your exact model before acting.

SLEEP function

Viessmann · SLEEP mode

Works in COOLING, HEATING or AUTO. In cooling the setpoint rises 2°F (1°C) per hour up to 86°F (30°C), stopping after two hours with fan on low. In heating the setpoint drops 2°F (1°C) per hour down to 62°F (17°C), stopping after two hours with fan on low (anti-cold wind has priority). Sleep runs 7 hours then the unit powers off.

Small filter installation on the air filter

Viessmann · DLFSHC indoor units

A small filter is supplied and must be fitted to the back of the main air filter by an authorized technician during installation. Quantity is 1 or 2 depending on model.

  1. Fit the small filter to the back of the main air filter.
  2. Confirm the quantity supplied for the model (1 or 2).

Standard features of DLCURAH outdoor units

Viessmann · All DLCURAH outdoor units

Standard on all sizes: inverter compressor, microprocessor controls, auto changeover and auto restart, 46°F heating setback (only with wireless remote used alongside wired controller KSACN1001), 3-minute compressor delay, high discharge temperature, low voltage, overload, over-current and IPM module protection, condenser high temperature protection in cooling, anti-corrosive coating, diagnostics, liquid line pressure taps, crankcase heater and base pan heater. Low voltage controls are standard.

Stop using the unit immediately if warning signs appear

Viessmann · Vitocal IND-O DLFSOAH, models 09XAK and 18XAK

Turn the unit off right away if the power cord is damaged or abnormally warm, if there is a burning smell, loud or abnormal sounds, a fuse blows or the breaker keeps tripping, or water or objects get into or out of the unit. Do not try to fix these yourself.

  1. Turn the unit off immediately.
  2. Contact an authorized service provider.

System operation recommendations

Viessmann · All models

Owner guidance for reliable operation.

  1. Replace both remote batteries at the same time.
  2. Point the remote at the unit display when sending commands.
  3. Keep doors and windows closed while running.
  4. Do not clean or service the unit while it is on.
  5. Keep the unit display away from direct sunlight and heat, which can disrupt the remote.
  6. Do not block air intakes or outlets on indoor or outdoor units.

Troubleshooting tools and approach

Viessmann · Troubleshooting

Tools: digital multimeter, Phillips and straight screwdrivers, needle-nose pliers, refrigeration gauges. Check indoor codes first, then consult the troubleshooting flowcharts (Table 6) and diagnosis pages. Problems without a code are covered by the flowcharts.

  1. Pick the problem from Table 6 and go to the matching diagnosis chart.
  2. Check the indoor unit display code first.
  3. Check the outdoor board first when measuring board signals.

Unit protection and controls

Viessmann · DLCURA outdoor units

The unit has a time delay control sequence on the fan coil board and automatic outdoor fan motor protection. Safeties include system diagnostics, compressor motor current and temperature overload protection, and outdoor fan failure protection.

  1. If the compressor will not start, check for the time delay sequence before condemning parts.
  2. If the outdoor fan stops, check the fan motor's internal thermal protection and the fan failure safety.
  3. Use the system diagnostics on the control to find which safety has tripped.

Wireless remote control

Viessmann · DLFSCBH and DLFLCBH

The wireless infrared remote is battery operated and supplied with all in-ceiling cassette units. One remote can control more than one indoor unit.

Wireless remote use

Viessmann · All cassette ductless systems

One battery-powered infrared remote can control more than one indoor unit.

  1. Use the wireless remote supplied with each cassette system.
  2. One remote can be assigned to multiple units.

Wiring and installation rules before power-up

Viessmann · All sizes

Check these points before energising the system.

  1. Use the electrical data table to size the disconnect fuse or breaker (MOCP) and the wire (MCA).
  2. Keep at least 10 ft (3 m) of refrigerant line between the indoor and outdoor units.
  3. Insulate the liquid and suction lines separately.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.