Other: Mini-Split tips (part 7 of 8)

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on other for mini-split. Check each one against the manual for your exact model before acting.

Isolate power before servicing

Viessmann · All service work on the indoor unit

Main electrical disconnect must be OFF before installing, modifying or servicing the unit. There may be more than one disconnect.

  1. Switch off all disconnects.
  2. Lock out and tag each switch with a warning label.

Leak testing and pressurising

Viessmann · DLCURA refrigerant circuit

Never use air or gases containing oxygen for leak testing or running refrigerant compressors. Mixtures of air and oxygen can explode.

LED display light on/off

Viessmann · Wireless remote

Turns the display light on or off from the remote.

  1. Press LED to toggle the display light.

Lock out power before service

Viessmann · DLCURA system

Before installing, modifying or servicing the system, the main electrical disconnect must be OFF. There may be more than one disconnect.

  1. Switch off the main disconnect.
  2. Check for additional disconnects.
  3. Lock out and tag each switch with a warning label.

Louver position memory

Viessmann · Louver control

When restarted, the louver returns to the angle the user set if it is within range. If the louver exceeds range, the unit stores the maximum allowed angle. After power failure or a shutdown in TURBO mode, the louver returns to the default angle.

  1. Confirm louver angle after restart.
  2. Expect the default angle after power failure or TURBO shutdown.

Never use the compressor as a vacuum pump

Viessmann · All sizes

Running the system compressor to pull a vacuum can damage equipment or cause improper operation.

  1. Do not use the system compressor as a vacuum pump.

Outdoor unit compatibility

Viessmann · DLFSDAH and DLFLDAH indoor units

The indoor units are backward compatible with listed single zone and multi-zone outdoor units. Check the current compatibility chart before pairing.

  1. Pair with 38MAQ sizes 09K to 24K, 38MBQ sizes 36K to 48K, or 38MGQ multi-zone systems.
  2. Check the current compatibility chart for the exact indoor and outdoor match-up.

Outdoor unit service access and coil cleaning

Viessmann · DLCLRC outdoor units

Removing the top panel (36K) or side panel (48K and 58K) gives access to the control compartment. Coils are draw-thru and can be cleaned from the inside with a pressure hose and detergent.

  1. Remove the top panel on the 36K or the side panel on the 48K and 58K to reach the control compartment.
  2. Clean the coil from the inside outward with a pressure hose and detergent.
  3. Check that base pan drain holes are open, or use the RCD rubber plugs if the condensate must be redirected.

Performance tables on pages 72 to 80 are for the AE Console

Viessmann · D5CSRA AE Console cooling performance

Pages 72 to 80 contain the 9K, 12K, 18K and AE console cooling grids. The table titles and CFM values change from page to page, so confirm the table title on each page before taking a reading.

  1. Confirm the table title (Table 28, 29 or 30 - AE Console) at the top of each page.
  2. Confirm the capacity in the title (9K, 12K or 18K) matches the outdoor unit you are checking.
  3. Use the continued-table pages with the same title and the matching airflow block.

Periodic maintenance schedule

Viessmann · Vitocal IND-F floor console, Size 12 (12XAK)

The schedule covers indoor and outdoor unit tasks. Increase the frequency in dusty areas. Outdoor tasks marked with a dagger need qualified service personnel.

  1. Indoor unit: clean the air filter monthly (more often in dusty zones).
  2. Indoor unit: replace the carbon filter, washing it every 6 months and replacing it yearly.
  3. Indoor unit: change the remote control batteries.
  4. Outdoor unit: clean the coil from the outside, and clean the drain pans and fan wheel by qualified personnel.
  5. Outdoor unit: qualified personnel should blow air over electric parts, check electrical connections and fan tightening, and clean the coil from the inside.
  6. Refer to the Installation Manual for qualified service work.

Piping routing when outdoor unit is higher than indoor unit

Viessmann · DLFSHC refrigerant piping

If the outdoor unit sits higher than the indoor unit, install an inverted trap in the connection pipe. This keeps rain from running into the wall before it reaches the indoor unit.

  1. Place an inverted trap in the connection pipe when the outdoor unit is above the indoor unit.
  2. Check that rain drips from the connection pipe before it enters the wall.

Power and communication wiring between indoor and outdoor unit

Viessmann · DLFSHC indoor and outdoor unit interconnect

Main power is supplied to the outdoor unit. The field-supplied 14/3 cable carries four wires: two high-voltage AC, one communication and one ground. Wiring is polarity sensitive. Do not use BX cable. Disconnecting the outdoor unit also de-energizes the indoor unit.

  1. Size wires per NEC or CEC and local codes, using the outdoor unit MCA and MOCP.
  2. Use 14/3 cable with four wires: two AC power, one communication, one ground.
  3. Keep the polarity of the indoor-to-outdoor wiring correct.
  4. Do not use BX cable.
  5. Where EMF interference causes communication faults, 14/2 stranded shielded wire may replace wires 2 and 3, with the shield grounded at the outdoor unit only.
  6. Make every connection tight and keep wires away from refrigerant tubing, the compressor and moving parts.

Power wiring procedure

Viessmann · DLCURA outdoor units

Field power connection to the outdoor unit.

  1. Remove the electrical cover of the outdoor unit.
  2. Connect each fork terminal to its matching terminal, matching the wire labels.
  3. Tighten each fork terminal firmly to its terminal.
  4. Insulate unused wires with electrical tape and keep them clear of electrical and metal parts.
  5. Reinstall the electrical control box cover.

Pre-season and long non-use inspection

Viessmann · Indoor and outdoor units

Do this after long periods of non-use or before frequent use.

  1. Clean all filters.
  2. Run FAN function until the unit dries out completely.
  3. Turn off the unit and disconnect the power.
  4. Check for damaged wires.
  5. Check for leaks.
  6. Make sure nothing blocks the air inlets and outlets.

Preparing for extended shutdown

Viessmann · Vitocal IND-F floor console, Size 12 (12XAK)

Dry the internal parts before the unit is left idle for a long time.

  1. Clean the filters and refit them in the unit.
  2. Run the unit in FAN ONLY mode for 12 hours to dry the internal parts.
  3. Turn the main power supply off.
  4. Remove the batteries from the remote control.

Protection features built into the system

Viessmann · All DLFSDAH and DLFLDAH systems

The indoor units have freeze and high temperature protection. Heat pumps also have cold blow protection, freeze protection mode and auto restart.

Rain protection when the outdoor unit is higher than the indoor unit

Viessmann · Field-installed refrigerant piping

Stop rain running down the connection pipe into the indoor unit.

  1. Form a downward arc in the connection pipe before it enters the wall to the indoor unit so rain drips off before reaching the wall.

Reading the serial number

Viessmann · DLCURA outdoor units

The serial is built from week of manufacture, year of manufacture, a model letter (V = all models) and a sequential serial number. The manual's example reads 49 22 V 10001.

Refrigerant service access points

Viessmann · DLCURA outdoor units

The refrigerant circuit has a brass external liquid line service valve with a gauge port, a suction line service valve with a gauge port, and Schrader-type gauge ports with brass caps on the compressor suction and discharge lines. The liquid line also has pressure taps.

  1. Use the liquid line service valve and suction service valve gauge ports to read system pressures.
  2. Use the compressor suction and discharge Schrader ports for compressor-side readings.
  3. Replace the brass caps on the Schrader ports after service.

Relocate IR receiver for wireless remote

Viessmann · Wireless remote control with IR receiver

The factory IR receiver sits inside the control box. If the wireless remote is used, move the receiver into line of sight of the remote position using the 6 ft cable. A wired controller IR can be used together with the wireless remote.

  1. Route the IR receiver to a spot in line of sight of the remote position using the 6 ft cable.

Remote control range and timer limits

Viessmann · Wireless remote control

The remote works up to 26 ft (8 m) with no obstructions. Timer use requires the remote to stay within 26 ft of the unit.

  1. Keep the remote within 26 ft (8 m) with a clear line of sight.
  2. Keep the remote near the unit when using the timer.

Replace remote control batteries

Viessmann · Wireless remote control

Use two new AAA 1.5 V alkaline batteries. Remote settings are erased when the batteries are removed, so reprogram the remote after new batteries go in. Replace batteries when the unit gives no beep or the transmission indicator does not light.

  1. Slide the back cover off the remote.
  2. Insert two AAA alkaline batteries, matching the polarity marks.
  3. Replace the battery cover.
  4. Reprogram the remote settings.
  5. Remove batteries if the remote will sit unused for several weeks.

Run the unit in AUTO mode

Viessmann · Single-zone installs

In AUTO the unit picks COOL, FAN or HEAT on its own based on the set point. Fan speed cannot be set in AUTO. Manual says AUTO is for single-zone use only.

  1. Press MODE until AUTO is selected.
  2. Set the temperature with TEMP up or down.
  3. Press ON/OFF to start the unit.

Run the unit in COOL mode from the remote

Viessmann · All sizes, wireless remote

Basic cooling operation from the wireless remote. Make sure the unit is plugged in and has power first.

  1. Press MODE until COOL is selected.
  2. Set the room temperature with the TEMP up or down buttons.
  3. Press FAN to pick a fan speed (AUTO, LOW, MED, HIGH, TURBO).
  4. Press ON/OFF to start the unit.

Run the unit in DRY (dehumidify) mode

Viessmann · All sizes

Dries and slightly cools the air. It is not a substitute for a dehumidifier.

  1. Press MODE until DRY is selected.
  2. Set the temperature with TEMP up or down.
  3. Press ON/OFF to start the unit.

Run the unit in FAN-only mode

Viessmann · All sizes

Filters and circulates room air without changing room temperature.

  1. Press MODE until FAN is selected.
  2. Press FAN to pick the speed.
  3. Press ON/OFF to start the unit.

Run the unit in HEAT mode from the remote

Viessmann · Heat pump models

Heating operation from the wireless remote. Heating output drops as outdoor temperature falls, so the manual recommends pairing it with other heating appliances in cold weather.

  1. Press MODE until HEAT is selected.
  2. Set the room temperature with TEMP up or down.
  3. Press FAN to pick a fan speed.
  4. Press ON/OFF to start the unit.

Serviceability and diagnostics

Viessmann · Outdoor and indoor units

Remove the top panel on the outdoor unit to reach the control compartment. Clean the outdoor coil from the inside with a pressure hose and detergent. Indoor units have easy access service panels and self-diagnostics.

  1. Remove the top panel on the outdoor unit to access the control box.
  2. Clean the outdoor coil from the inside with a pressure hose and detergent.

Shipping, storage and handling

Viessmann · DLCURA outdoor units

Units ship in one piece. Store and handle them according to the manufacturer's recommendations.

  1. Keep the unit upright and store it per the manufacturer's handling instructions.

SILENCE operation

Viessmann · Remote control SILENCE button

Press SILENCE on the remote. Compressor frequency stays below F2 and the indoor unit gives a faint breeze to lower noise.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.