Air vent and drain tubing

Viessmann · Vitotron 100 VLN2 heat exchanger

The air vent sits on top of the heat exchanger and removes air from the boiler.

  1. Confirm the plastic drain tubing from the air vent is still in place.
  2. Confirm the tubing exits the boiler in the lower right corner.
  3. Purge air from the whole system and its components.

Air venting between trap and neutralization unit

Viessmann · Condensate neutralization

Pipe ventilation must be provided between the siphon trap and the neutralization unit.

  1. Vent the piping between the siphon trap and the neutralization unit, where one is fitted.

Alcove top clearance depends on the control

Viessmann · Alcove installs

Alcove top clearance is 6 in (150 mm) in the standard listing. With Vitotronic control the top clearance is 24 in.

Alternative DHW connection piping layout

Viessmann · Vitodens 222-F, B2TB (19, 35, 68, 125)

Reference piping layout for connecting the domestic hot water (DHW) system to the boiler. Key parts: boiler heat exchanger, DHW heat exchanger, boiler pump, DHW circulating pump, diverting valve, expansion tank, flow check valve, water softener if fitted, and temperature and pressure relief valve outlet. Check the legend letters against the drawing on site.

Alternative DHW connection with diverting valve

Viessmann · Vitodens 222-F B2TB, external DHW storage with diverting valve

Alternative piping where the boiler heats a separate DHW heat exchanger through a diverting valve, instead of the integrated tank. Includes an optional DHW recirculation loop.

  1. Pipe the boiler supply and return to the diverting valve and the boiler heat exchanger as shown.
  2. Connect the DHW heat exchanger and the DHW storage tank.
  3. Install a water softener on the DCW inlet where water hardness requires it.
  4. If a DHW recirculation pump is used, install a flow check valve in the recirculation line.
  5. Fit the temperature and pressure relief valve outlet and pressure relief valve outlet to drains.

Altitude derate for input capacity

Viessmann · Vitocrossal 300 CA3B Dual Fuel 2.5 to 6.0

Input must be derated for elevation. Up to 4,999 ft, derate 3% per 1,000 ft. From 5,000 to 10,000 ft, with the electronic altitude adjustment made, derate an extra 0.6% per 1,000 ft, for a total derate of 18%.

  1. Check the installation altitude.
  2. Up to 4,999 ft, derate input 3% per 1,000 ft.
  3. From 5,000 to 10,000 ft, make the electronic altitude adjustment, then derate an additional 0.6% per 1,000 ft (18% total).

Altitude operation without input derate

Viessmann · Vitocrossal 200 CI2, all sizes

The Lambda PrO2 combustion system adjusts the burner to oxygen level at each input rate. Combined with the electronic elevation setting in the boiler software, the boiler runs up to 10,000 ft (3,000 m) without input derate.

  1. Set the elevation in the boiler software for the install altitude.
  2. Confirm combustion values with the combustion test at commissioning.

AM1 pump connections A1 and A2

Viessmann · AM1 extension module

Up to two circulation pumps can be connected to outputs A1 and A2: heating circuit pump without mixing valve or zone pump, DHW tank heating pump, or DHW recirculation pump.

  1. Assign the pump function to each output with the codes on the boiler control unit.
  2. Follow the AM1 module installation instructions.

Annual inspection and service

Viessmann · Vitodens 100-W B1HE/B1KE

The boiler, burner and controls must be checked at least once a year by the original installer or a competent heating contractor. Defects must be corrected right away.

  1. Schedule a service inspection once a year, ideally before the heating season.
  2. Follow the Viessmann maintenance schedule and the cleaning and maintenance steps in the installation instructions.
  3. Correct any defects found immediately.

Annual magnetic filter cleaning

Viessmann · Vitotron 100 VLN2

The magnetic filter protects the flow sensor inside the boiler. Clean it at least once a year, because residue left in the filter can contaminate the boiler.

  1. Remove the pre-installed magnetic filter.
  2. Clean the filter.
  3. Reinstall the filter and check system pressure.

Annual service and owner handover

Viessmann · Vitorond 200 VD2

Once installation is complete, the contractor must train the owner and state that annual professional service is needed before each heating season.

  1. Walk the owner through the equipment, safety requirements and shutdown procedure.
  2. Tell the owner professional service is needed every year before the heating season.
  3. Follow the Viessmann maintenance schedule in the Service Instructions manual.

Annual service requirement

Viessmann · Vitocrossal 300 CU3A, all models

The boiler, burner and controls must be checked at least once a year by the original installer or a competent heating contractor. Defects must be corrected immediately.

  1. Schedule a yearly inspection by a qualified heating contractor before the heating season.
  2. Correct any defects found right away.

Antifreeze and water quality

Viessmann · System water treatment

Treat feed water where minerals or hardness are high. Antifreeze may be used where freezing can occur, but only glycol made for hot water heating systems.

  1. Do not use automotive silicate-based antifreeze.
  2. A 40% antifreeze content gives freeze protection to -10 °F (-23 °C).
  3. Follow the antifreeze manufacturer's specifications.
  4. Check the system frequently when filled with antifreeze.
  5. Provide the system owner an MSDS for the antifreeze and advise that the system contains glycol.
  6. Check whether antifreeze may need a backflow preventer, and check diaphragm tanks and radiation for compatibility.

Antifreeze and water treatment

Viessmann · Vitorond 200 VD2A hydronic systems

Use only antifreeze made for hot water heating systems and follow the antifreeze maker's specifications.

  1. Consider water treatment where feed water has high mineral content or hardness.
  2. Use 40% antifreeze content to protect to -10°F (-23°C).
  3. Do not use automotive silicate-based antifreeze.
  4. Check the whole system often when it is filled with antifreeze, and check for a backflow preventer in the auto fill line.

Appendix B relay state references

Viessmann · AI6, AI12, AI18, AI24, AI26

Relay state values are listed in Appendix B, which is outside these pages.

Applicable boiler controls

Viessmann · Versatronik 511 and 511D Type B gateways

The gateway works with these Viessmann controls: Vitotronic 100 GC1/GC1B, Vitotronic 300 GW2, Vitotronic 300 GW5B, Vitotronic 200 HO1 and Vitodens 200 B2HA. The Type B gateway is for multi-LON boiler controls that do not talk to a Vitocontrol Cascade control.

Applicable codes for installation

Viessmann · All installations

Installation must follow local codes first. Where no local code applies, the listed national codes are used.

  1. Canada gas: CAN/CSA-B149.1 or .2.
  2. USA gas: National Fuel Gas Code ANSI Z223.1.
  3. Canada electrical: CSA C22.1 Part 1 and/or local codes.
  4. USA electrical: National Electrical Code ANSI/NFPA 70.
  5. Controls and safety devices: ANSI/ASME CSD-1 where the authority having jurisdiction requires it.

Application 10 application code

Viessmann · Vitocrossal CU3A Application 10

Application 10 is identified by the application code 4CU3I 2HC2ZP.01 printed on the drawing.

Application 1: hydraulic separation with low loss header or closely spaced tees

Viessmann · Vitodens 222-F Application 1

Separates the boiler loop from the system loop so their flows do not affect each other. The boiler circulator P1 is built in. A low loss header sensor can be added for better control and efficiency.

  1. Install a low loss header or closely spaced tees on the system loop.
  2. Confirm the boiler flow is within its recommended range (see sizing and flow pages referenced in the manual).
  3. Connect the outdoor sensor and the low loss header sensor if used.
  4. Connect the thermostat, or use a Vitotrol 200-A or 300-A in place of a standard thermostat.
  5. Set the application code VD2T 1HC1T1ZP.01 as shown in the manual.

Application 5 system overview

Viessmann · Vitodens 222-F, B2TB, Application 5

Low temperature heating circuit with a 3-way mixing valve (HC2), plus a high temperature zone (ZC1). The ZC1 call starts the 28/20 plug pump for the high temperature zone. HC2 mixing follows the heating curve set in the boiler control.

  1. Wire the ZC1 thermostat to the DE connections and the pump to the 28/20 output.
  2. Leave the HC2 mixing valve on the boiler heating curve settings.

Application 6 wiring and thermostat notes

Viessmann · Vitodens 222-F, B2TB, Application 6

Thermostats may be replaced by Vitotrol room controls to give a communicating room control. Only one control can be selected per heat circuit, either a thermostat or a Vitotrol. The P1 boiler circulator is built into the boiler. External flow check valves are not needed where they are built into the circulators.

  1. Pick one control per heat circuit: a thermostat or a Vitotrol.
  2. Do not add external check valves where the circulators already have them.
  3. Use the sizing and flow pages referenced in the manual for pump and flow sizing.

Application 8 design notes

Viessmann · Application 8 (2CU3I 3HC/ZC3ZP.01)

Design notes for the Application 8 layout.

  1. Note that the air handler circulator is not controlled by the boiler, so higher than design water temperatures can reach the air handler during DHW calls.
  2. CU3A is a high mass boiler, so primary/secondary piping is not required.
  3. The low loss header can be replaced with closely spaced tees (see Application 9).
  4. Cascade control max load is 6 amps. Use isolation relays if multiple circulators and mixing valve motors are used.
  5. P5 is controlled internally by the air handler.
  6. Verify mixing valve motor stroke direction with an actuator test (see Cascade Control Installation & Service Manual).

Application 8 operating concept

Viessmann · Application 8

Low temperature heat circuit with motorized mixing valve, hot water forced air fan coil, indirect DHW, and a two-boiler cascade with low loss header. The cascade control targets the highest system temperature. The mixing valve sets supply temperature for the low temperature circuit regardless of the temperature for the other circuits. Allows turndown, boiler redundancy, higher input, and simultaneous heating and DHW.

Application 9 application code

Viessmann · Vitocrossal CU3A Application 9

Application 9 is identified by the application code 2CU3I 4HC4ZP.01 printed on the drawing.

Application 9 design notes

Viessmann · Application 9 (2CU3I 4HC4ZP.01)

Design notes for the Application 9 layout with three heating circuits and a heat exchanger.

  1. External flow check valves are not needed if the circulators already have them built in.
  2. HC3 is separated from the system by a heat exchanger. An automatic fluid feeder may be desired.
  3. Based on recommended piping practice, install a pressure relief valve on the secondary side of the heat exchanger.
  4. Cascade control max load is 6 amps. Use isolation relays if multiple circulators and mixing valve motors are used.
  5. Verify mixing valve motor stroke direction with an actuator test (see Cascade Control Installation and Service Manual).

Application code 2CU3I 3HC/ZC3ZP.01

Viessmann · Application 8

Application code for Application 8, the two-boiler cascade with mixing valve, air handler, and indirect DHW.

Application code 2CU3I 4HC4ZP.01

Viessmann · Application 9

Application code for Application 9, the layout with four heating circuits and a heat exchanger.

Application index for Vitodens 222-F B2TB

Viessmann · Vitodens 222-F B2TB

Application codes listed in the guide and the pages where each is shown.

  1. Application 1: VD2T 1HC1T1ZP.01, page 26.
  2. Application 2: VD2T 1HC1T4ZV.01, page 30.
  3. Application 3: VD2T 1HC1T4ZP.01, page 34.
  4. Application 4: VD2T 2ZC2T2ZP.01, page 38.
  5. Application 5: VD2T 2ZC/HC2T2ZP.02, page 42.
  6. Application 6: VD2T 3HC3T3ZP.01, page 46.

Approved boilers for KW10B

Viessmann · Vitotronic 100 KW10B, serial no. V00101 and up

This control is only approved for use with the Vitola 200, Vitorond 100, Vitogas 050, RS Series, or Vitogas 100 hot water heating boilers. Applies to serial no. V00101 and later.

Balanced flue and combustion air inlet setup

Viessmann · Vitodens 222-F B2TB

A factory vent adaptor C comes installed. Run the vent single-wall or coaxial through the side wall or roof on the shortest route, rising at least 3 degrees. Support the piping so it does not rest on the boiler.

  1. Remove the outer gasket from vent adaptor C if using a single-wall, room-air-dependent system.
  2. For B2TB combustion air, remove inlet seal A, tear out the center section, and reinstall the rubber seal in the air inlet opening.
  3. Seal or shield building surfaces exposed to flue products (e.g. aluminum sheeting) before attaching the vent termination.
  4. Install the vent termination on the leeward side of the building where possible.
  5. Connect the balanced flue per the Venting System Installation Instructions.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.