Energy-efficient mode (Gear button)

Carrier · Single-zone systems

Pressing the Gear button on the remote cycles through the energy-efficient mode sequence. Turning the unit off or activating ECO, sleep, Super cool, 8°C heating, Silence or self clean ends this function. Not available on multi-zone systems.

  1. Press the Gear button on the remote to enter the energy-efficient mode sequence.

Exit inquiry mode

Carrier · D5FSOAH indoor unit

Leaves the service inquiry menu and returns to normal display.

  1. Press and hold On/Off and Fan together for 2 seconds.

Fireplace operation from the BOOST button

Carrier · Wireless remote controller, heating mode

In heating mode, holding BOOST for more than 5 seconds starts fireplace operation. Holding it for more than 3 seconds stops it.

  1. Set the unit to HEAT mode.
  2. Press and hold BOOST for more than 5 seconds to start fireplace operation.
  3. Press and hold BOOST for more than 3 seconds to stop it.

Follow Me memory feature

Carrier · Units with Follow Me

Starts or stops the Follow Me memory. The display shows ON or OFF for 3 seconds to confirm.

  1. Press and hold BOOST for seven seconds.

Forced AUTO and Forced COOLING operation

Carrier · Indoor unit with TOUCH button

Used to run the unit without the remote. With the unit off, press TOUCH once to start Forced AUTO. Press TOUCH again within 5 seconds to start Forced COOLING. In any forced mode, press TOUCH to turn the unit off. Protections and the remote remain active in forced operation.

  1. With the unit off, press TOUCH once to engage Forced AUTO.
  2. Press TOUCH again within 5 seconds to engage Forced COOLING.
  3. Press TOUCH to turn the unit off from any forced mode.

Forced operation (test) mode

Carrier · D5FSOAH indoor unit

Forces the unit to run without the remote. Protections and remote control are still active in this mode.

  1. With the unit off, press TOUCH to start FORCED AUTO (75.2 F / 24 C setpoint).
  2. Press TOUCH again within 5 seconds to start FORCED COOLING.
  3. Press TOUCH once more to turn the unit off from any forced mode.

Forced operation (TOUCH button)

Carrier · D5FCFAH

With the unit off, press TOUCH to start FORCED AUTO at 75.2°F (24°C). Press TOUCH again within 5 seconds for FORCED COOLING. Press TOUCH in any forced mode to turn the unit off. General protections and remote control stay active.

  1. Press TOUCH once with unit off to start FORCED AUTO.
  2. Press TOUCH again within 5 seconds to start FORCED COOLING.
  3. Press TOUCH to stop the unit.

Forced operation using the TOUCH button

Carrier · D5FSFAH 9K to 16K

Forced operation works without the remote and keeps the general protections and remote controller active.

  1. With the unit off, press TOUCH once to start Forced AUTO mode.
  2. Press TOUCH again within 5 seconds to switch to Forced COOLING mode.
  3. Forced COOLING runs at compressor frequency F2 with the indoor fan on BREEZE. After 30 minutes it switches to AUTO at 75.2 F (24 C).
  4. To stop the unit from any forced mode, press TOUCH.

Lock or unlock the wireless remote

Carrier · Wireless remote RG10L5(2HS)

Locking or unlocking the remote is done by holding two buttons together.

  1. Hold the BOOST and HUMIDITY buttons together for 5 seconds to lock or unlock the remote.

Silence feature shortcut

Carrier · Single-zone D5FCFAH systems

Press SILENCE, or hold FAN for more than 2 seconds, to enable the SILENCE function. The indoor unit runs at faint breeze and the compressor is held at a lower frequency. Not available on multi-zone systems.

  1. Press SILENCE, or hold FAN for more than 2 seconds, to enable it.

SILENCE function (not on multi-zone systems)

Carrier · D5FCFAH

Press SILENCE or hold the FAN button for more than 2 seconds to enable. Compressor frequency is held lower than the set limit and the indoor unit runs at faint breeze. Disabled when matched to multiple outdoor units. The source gives both F2 and F3 as the frequency limit; confirm which applies.

  1. Press SILENCE on the remote control, or hold FAN for more than 2 seconds.
  2. Confirm the indoor unit is on faint breeze.

SILENCE mode

Carrier · Wireless remote controller

Keeps compressor frequency below F2 and runs the indoor unit at a faint breeze for the lowest noise level.

  1. Press SILENCE on the remote to start Silence mode.
  2. Turning the unit off, or activating ECO, sleep, Super cool, 8°C heating or self clean, ends Silence mode.

Start or stop the FOLLOW ME memory feature

Carrier · Wireless remote controller, FOLLOW ME function

Holding BOOST for 7 seconds toggles FOLLOW ME memory. The memory setting survives ON/OFF, MODE changes and indoor power failure.

  1. Press and hold BOOST for 7 seconds.
  2. Watch the display: ON shows for 3 seconds when memory starts, OFF shows for 3 seconds when it stops.

Start vertical louver auto swing

Carrier · Wireless remote control

The SWING button starts and stops the horizontal louver. Holding it longer starts vertical auto swing.

  1. Hold the SWING button for 2 seconds.

Switch display between F and C

Carrier · Wireless remote RG10F8(2)/BGEFU1

The remote can show temperature in Fahrenheit or Celsius. Default is Fahrenheit.

  1. Press the + and - temperature buttons together for about 3 seconds to switch between F and C.

Switch display between °C and °F

Carrier · Wireless remote RG10L5(2HS)

Both temperature buttons are pressed together to switch the temperature display units.

  1. Press the two temperature buttons together for 3 seconds to switch between °C and °F.

Switch display between °F and °C

Carrier · Wireless remote control

Press the two temperature buttons together for about 3 seconds to toggle the remote display between Fahrenheit and Celsius.

  1. Press both TEMP buttons together and hold for 3 seconds.

Switch the display between F and C

Carrier · D5FCFAH wireless remote controller

Press and hold the TEMP up and TEMP down buttons together for about 3 seconds to toggle the remote temperature display between Fahrenheit and Celsius.

  1. Press and hold both TEMP buttons together for about 3 seconds.

Switch the remote between Celsius and Fahrenheit

Carrier · Wireless remote controller

Hold the up and down TEMP buttons together for about 3 seconds to toggle the display between degrees C and degrees F.

  1. Press and hold TEMP up and TEMP down together for about 3 seconds.
  2. Check the display to confirm the new unit.

Switch the remote display between °F and °C

Carrier · Wireless remote control

Press the two temperature buttons together to switch the display units.

  1. Press TEMP up and TEMP down together.
  2. Hold for 3 seconds.

Vertical louver auto swing

Carrier · D5FCFAH wireless remote controller

Hold the SWING button for 2 seconds to start the vertical louver auto swing feature. A short press starts and stops horizontal louver movement.

  1. Hold SWING for 2 seconds to start vertical auto swing.
  2. Press SWING briefly to start or stop horizontal louver movement.

Enter AP mode to configure Wi-Fi

Viessmann · Units with WiFi module (Wi-Fi interface kit KSAIF0301AAA sold separately)

Used to set up the wireless network on units with the Wi-Fi interface kit.

  1. Continuously press LED seven times within 10 seconds.

Forced operation (no remote)

Viessmann · Indoor unit TOUCH button

Used when the unit is off and no remote is available. Press TOUCH to start FORCED AUTO (75.2°F / 24°C setpoint). Press TOUCH again within five seconds for FORCED COOLING. Press TOUCH in any forced mode to turn the unit off. General protections and remote control remain active.

  1. With unit off, press TOUCH once for FORCED AUTO.
  2. Within 5 seconds, press TOUCH again for FORCED COOLING.
  3. Press TOUCH to turn the unit off.

Manual switch on the indoor unit

Viessmann · All sizes

The manual switch on the indoor unit runs the unit without the remote. Pressing it once energises the unit; pressing it twice more switches it off.

  1. Open the indoor unit's front panel.
  2. Press the manual switch once to start manual operation.
  3. Press it twice more to return the switch to OFF after testing.

SLEEP mode

Viessmann · Vitocal IND-F floor console, Size 12 (12XAK)

SLEEP saves energy in COOL, HEAT or AUTO. It is not allowed in DRY or FAN.

  1. Press SLEEP to start it.
  2. In COOLING, the set point rises 1°C after one hour, then another 1°C after a second hour, and the fan runs on low.
  3. In HEATING, the set point is lowered 1°C from the normal setting.
  4. The unit shuts off 5 hours after SLEEP is set.
  5. Pressing MODE, TEMP, FAN, TIMER or ON/OFF cancels SLEEP.

Start or stop FOLLOW ME memory

Viessmann · Wireless remote with FOLLOW ME

The remote keeps measuring room temperature at its location. Memory mode stays on through ON/OFF, MODE and indoor unit power failure.

  1. Press and hold BOOST for 7 seconds to start or stop FOLLOW ME MEMORY.
  2. Check the display: 'ON' shows for 3 seconds when started, 'OFF' when stopped.

Start vertical louver auto swing

Viessmann · Wireless remote control

Holding the SWING button for 2 seconds starts the vertical louver auto swing. A short press starts and stops horizontal louver movement.

  1. Press SWING briefly to start or stop horizontal louver movement.
  2. Hold SWING for 2 seconds to start vertical louver auto swing.

Switch display between °F and °C

Viessmann · Wireless remote, all modes

Default unit is °F. Hold both temperature set point buttons together to change it.

  1. Point the remote at the unit.
  2. Press and hold the + and - temperature buttons together for about 3 seconds.

Switch remote between °F and °C

Viessmann · Wireless remote control

Press and hold both TEMP buttons together for about 3 seconds to change the remote display between °F (default) and °C.

  1. Press and hold TEMP up and TEMP down together for about 3 seconds.

Switch temperature display between °F and °C

Viessmann · Wireless remote control

Hold the two temperature buttons together to toggle the display units.

  1. Press the two TEMP buttons together and hold for 3 seconds.
  2. Confirm the display shows the new unit (°F or °C).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service