Riello Boiler: Riello 40 pump seal leaking or failed
Riello 40 pump seal leaking or failed on a Riello boiler: The pump shaft seal is easy to damage by the wrong oil line set-up.
Applies to: Riello 40 F5 burner on Weil-McLain Ultra Oil UO-3, UO-4, UO-5
Common causes of riello 40 pump seal leaking or failed
- By-pass plug installed on a single-line (gravity) system
- Blocked or restricted return line on a two-line system
- Burner run before oil lines were connected
- NPT fittings forced into the pump's metric (British parallel) ports, or pipe dope / Teflon on pump connections
How to fix riello 40 pump seal leaking or failed: step by step
- Single-line system: by-pass plug must NOT be in the pump. Two-line system: by-pass plug must be in the return port (use the 2.5 mm metric hex key).
- On two-line systems, check the return line is open, same size as the supply, and both reach the same depth in the tank.
- Use the supplied adapters on the pump ports. No pipe dope or Teflon tape on direct pump connections.
- Check suction: lift height no more than 13 ft (4 m) and vacuum no more than 11.44 in. Hg. Check line lengths against the charts on p.9-10.
- Make sure an external oil filter is installed between tank and pump, and change it yearly.
Source: Riello 40 F3/F5 oil burner installation & operating manual C6501071 (Weil-McLain Ultra Oil edition), Oil line connections p.9-10. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.