Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Riello Boiler: Purge air from the Riello 40 pump

Updated · by Aurora Star Tech Inc.

Purge air from the Riello 40 pump on a Riello boiler: How to bleed the pump on gravity (one-pipe) and lift (two-pipe) systems.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Riello 40 F5 burner on Weil-McLain Ultra Oil UO-3, UO-4, UO-5

How to fix purge air from the riello 40 pump: step by step

  1. On a lift system, put a little oil into the vacuum port first to lubricate the pump gears.
  2. One-pipe, simple way: open the bleeder until oil runs, close it and start the burner.
  3. One-pipe under pressure: open the bleeder, disconnect the nozzle line at the pump nozzle port and run a plastic tube to a bucket. Start the burner holding the air tube cover in place. When the valve opens (about 10 s), lift the cover and shine a light on the photocell so it keeps running. When the oil is free of air, close the bleeder and shut the burner off right away. Reconnect the nozzle line and refit the cover.
  4. Never skip the step of disconnecting the nozzle line on a pressure bleed. Otherwise unburned oil collects in the chamber.
  5. Two-pipe: power off, remove the air tube cover, shine a light on the photocell, power on and call for heat. The burner stays in pre-purge while the pump primes. When the hydraulic shutter opens, the pump is purged. Power off and refit the cover.
  6. Check all oil line joints for air leaks.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Source: Riello 40 F3/F5 oil burner installation & operating manual C6501071 (Weil-McLain Ultra Oil edition), Pump purge p.10-11. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977