Napoleon Gas Fireplace: Venturi / air shutter adjustment
Venturi / air shutter adjustment on a Napoleon gas fireplace: The venturi (air shutter) sets how much primary air mixes with the gas, and that decides your flame colour. What I usually find is that a fireplace needs the air shutter set a bit different from the factory setting once the vent run, the fuel or the altitude is not what the factory assumed. This is a setup adjustment, not a repair. It matters on the GD70, which leaves the factory set for the longest horizontal run.
Applies to: Napoleon gas fireplaces - direct vent, natural vent and vent-free (general service manual); GD70 note from GD70 manual
Common causes of venturi / air shutter adjustment
- Air shutter not set for vent length, fuel or altitude
- Conversion between natural gas and propane
- Flame too yellow with sooting, or too blue and lifting off the ports
- GD70 installed with a shorter vent run than the factory setting assumes
How to fix venturi / air shutter adjustment: step by step
- Loosen the securing screw and rotate the venturi to open or close
- Closing gives a yellower flame but can cause carboning, opening gives a bluer flame but can lift flames off the ports
- Wait 15-30 minutes for the final flame colour before judging
- GD70: factory set for the longest horizontal run (20 ft), shorter runs need adjustment (propane can go as low as 1/4" open)
- Access by removing the two cover screws on the air housing without damaging the gasket
- WARNING: qualified gas installer only, and check the gasket seals again when you put the cover back
If the unit shows an error code, look it up: Napoleon Gas Fireplace codes
Models
Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 5 Testing & Adjustments, Adjustments: Venturi p.44; GD70 W415-0434 Maintenance section. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.