Napoleon Gas Fireplace: Pilot will not light
Pilot will not light on a Napoleon gas fireplace: No pilot ignition when the piezo push button is pressed.
Applies to: Napoleon GD70 STARfire direct-vent fireplace (GD70NT-S natural gas, GD70PT-S propane)
Common causes of pilot will not light
- No spark at the pilot (ignitor, wire or electrode problem)
- Propane tank empty
- Incorrect spark gap
- No gas reaching the pilot
How to fix pilot will not light: step by step
- Try lighting the pilot with a match to separate a spark problem from a gas problem.
- Confirm the electrode wire is connected to the push-button ignitor and the ignitor is tight; replace the wire if insulation is broken or frayed.
- Replace the electrode if its ceramic insulator is cracked or broken; replace the push-button ignitor if still no spark.
- Set spark gap to 0.150"-0.175" (approx. 5/32"-11/64") between electrode tip and pilot burner; tighten the securing nut finger-tight plus 1/4 turn.
- Propane units: check the tank and refill if empty.
- No gas at pilot: confirm the manual shutoff valve is on, check the pilot orifice for blockage, then replace the valve or call the gas supplier.
If the unit shows an error code, look it up: Napoleon Gas Fireplace codes
Models
Source: Napoleon GD70NT-S / GD70PT-S Installation & Operating Instructions W415-0434, Troubleshooting table, p.26. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.