Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Napoleon Gas Fireplace: Pilot goes out while standing (main burner OFF)

Updated · by Aurora Star Tech Inc.

Pilot goes out while standing (main burner OFF) on a Napoleon gas fireplace: Confirm the gas is shut off at the appliance and the pilot area is clear before you start poking around, and plan on a gas pressure test with a manometer. With the main burner off, the pilot on this Napoleon GD70 STARfire keeps going out, or flutters when another appliance or the main burner fires. That pattern points to a supply that can't keep up, usually undersized gas piping to the fireplace. A pilot that drops out all by itself with nothing else running needs a different look. Gas supply work is for a licensed technician.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Napoleon GD70 STARfire direct-vent fireplace (GD70NT-S natural gas, GD70PT-S propane)

Common causes of pilot goes out while standing (main burner off)

  • Gas supply piping undersized for the total connected load
  • Supply pressure dropping when other appliances start
  • Regulator or line restriction upstream of the fireplace

How to fix pilot goes out while standing (main burner off): step by step

  1. Turn on all gas appliances in the house and watch the pilot, fluttering, shrinking or going out (especially when the main burner lights) points to supply starvation
  2. Monitor the appliance supply working pressure while everything runs (spec NG 7" w.c. min 4.5"; propane 13" w.c. min 11")
  3. Note the pressure with only the pilot lit, then with all appliances at full fire, and compare the two readings
  4. Check supply pipe sizing against code and correct any undersized piping
  5. Look for a kinked flex connector or partly closed shutoff upstream
  6. Have a licensed gas fitter do any piping or regulator changes
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Napoleon Gas Fireplace codes

Models

GD70NT-SGD70PT-S

Source: Napoleon GD70NT-S / GD70PT-S Installation & Operating Instructions W415-0434, Troubleshooting table, p.26. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.