Napoleon Gas Fireplace: Pilot drops out during operation – vent-free
Pilot drops out during operation - vent-free on a Napoleon gas fireplace: Vent-free fireplaces rely on the oxygen depletion sensor (ODS) pilot, so a pilot that fails while the unit is running may just be doing its job. The ODS is built to shut the unit down when it senses low oxygen in the room. That makes room size and air supply as important as the electrical readings. Check the cheap items (pilot flame, ODS opening) first, then go on to pressure and millivolt tests.
Applies to: Napoleon vent-free gas fireplaces with ODS pilot (general service manual flowchart)
Common causes of pilot drops out during operation - vent-free
- Wrong pilot flame, size or position
- Pressure drop when the burner lights
- Low thermocouple output
- Weak magnet coil
- Inlet pressure too high or too low
- Dirty ODS air opening, because dust changes the pilot flame
- Room too small (not enough unconfined space)
- Logs out of place
How to fix pilot drops out during operation - vent-free: step by step
- Check pilot flame pattern, size and position, because the ODS reads the flame itself
- Check for pressure drop when the burner is activated
- Test thermocouple millivolts and the magnet coil, compare to the manual spec
- Test inline pressure, since too high pushes the pilot past the thermopile and too low prevents lighting
- Clean dirt and debris from the ODS primary air opening
- WARNING: confirm the room meets the unit's minimum unconfined-space requirement, and add make-up air if not
- Check log positions
- Do not replace or alter the ODS pilot assembly, use the correct part from the manufacturer
If the unit shows an error code, look it up: Napoleon Gas Fireplace codes
Models
Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 1-3 Troubleshooting, Pilot Failure Flowchart, p.21. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.