Napoleon Gas Fireplace: Pilot drops out during operation – direct vent

Updated · by Aurora Star Tech Inc.

Pilot drops out during operation - direct vent on a Napoleon gas fireplace: Pilot lights fine, then drops out once the unit is running. Direct-vent Napoleon, GD70NT-S and GD70PT-S included. Usually the pilot is sitting wrong, or the gas pressure sags when the main burner kicks in. Check the pilot first. Then pressure. Then vent and logs.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Napoleon direct-vent gas fireplaces (general service manual flowchart; applies to GD70NT-S/GD70PT-S)

Common causes of pilot drops out during operation - direct vent

  • Wrong pilot flame size or position
  • Pressure drop when burner comes on
  • Low thermocouple output
  • Weak magnet coil
  • Venting problem
  • Logs out of place

How to fix pilot drops out during operation - direct vent: step by step

  1. Check pilot flame pattern, size and position, it must properly heat the thermocouple
  2. If the pilot shrinks when the burner comes on, check for pressure drop on activation, that is a supply problem
  3. Test thermocouple millivolts (20-30 mV open, 10-15 mV closed)
  4. Test the magnet coil
  5. Inspect the vent system (see Complete Unit Shutdown guide)
  6. Check log positions, misplaced logs disturb airflow and make the pilot erratic
  7. If the supply pressure is the issue, a licensed gas technician should sort out the piping
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Napoleon Gas Fireplace codes

Models

GD70NT-SGD70PT-S

Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 1-3 Troubleshooting, Pilot Failure Flowchart, p.3. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.