Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Napoleon Gas Fireplace: Main burner will not light – natural vent

Updated · by Aurora Star Tech Inc.

Main burner will not light - natural vent on a Napoleon gas fireplace: Pilot is on but main burner will not fire on a natural-vent unit.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Napoleon natural-vent (B-vent) gas fireplaces with spill switch (general service manual flowchart)

Common causes of main burner will not light - natural vent

  • Pilot too small to reach burner ports
  • Low thermopile output
  • Low supply pressure
  • Spill or vent safety switch open
  • Blocked burner/orifice
  • No switch on terminals 1 & 3
  • Faulty switch/wiring
  • Bad operator coil

How to fix main burner will not light - natural vent: step by step

  1. Check pilot size and position - it must reach the ignition ports.
  2. Test thermopile millivolts and confirm it is connected.
  3. Test inline supply pressure.
  4. Test spill and vent safety switches for function and connection.
  5. Check and clean burner and orifice.
  6. Confirm a switch or remote is on terminals 1 & 3; jumper 1 & 3 to test - if the burner lights, the switch/wiring is at fault.
  7. If not, test the operator coil and replace the valve if out of spec.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Napoleon Gas Fireplace codes

Models

GD70NT-SGD70PT-S

Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 1-3 Troubleshooting, Main Burner Not Lighting Flowchart, p.13. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977