Napoleon Gas Fireplace: Exhaust fumes smelled in room / occupants get headaches
Exhaust fumes smelled in room / occupants get headaches on a Napoleon gas fireplace: If you smell exhaust in the room, or anyone is getting headaches while the fireplace runs, stop and shut the unit off first. On a direct-vent Napoleon GD70 the combustion system is supposed to be sealed from the room, so fumes in the room mean the fireplace is spilling. The cause may be a leaking door or relief flap seal, a blocked vent or chimney, or on a new unit just paint curing off. Headaches are the thing to take seriously because they can be carbon monoxide. Confirm with a CO test before anyone relights it.
Applies to: Napoleon GD70 STARfire direct-vent fireplace (GD70NT-S natural gas, GD70PT-S propane)
Common causes of exhaust fumes smelled in room / occupants get headaches
- Door seal or relief flap seal leaking
- Blocked chimney or vent
- Paint curing not yet complete on a new unit
- Damaged vent joints letting exhaust into the space
How to fix exhaust fumes smelled in room / occupants get headaches: step by step
- Shut the unit off, ventilate the room, and test for CO before further operation, since headaches with a fume smell can indicate carbon monoxide
- With the unit cold, check the door seal and the relief flap seal, repair or replace gaskets
- Check the vent or chimney for blockage at the terminal and along the run
- On a new unit confirm the paint curing (burn-in) process has been completed, the smell should fade
- If the smell is not from paint and CO shows up, keep the unit off and call a licensed gas technician
- Install or confirm a working CO alarm near the fireplace
If the unit shows an error code, look it up: Napoleon Gas Fireplace codes
Models
Source: Napoleon GD70NT-S / GD70PT-S Installation & Operating Instructions W415-0434, Troubleshooting table, p.25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.