PLEASE WAIT stays on, or an error shows about 2 minutes after power-up on a Mitsubishi heat pump: For about 2 minutes after power-up the remote shows PLEASE WAIT while the system starts - that is normal. If it is followed by an error code, or the screen stays blank with the ON button doing nothing, there is a wiring or protection problem.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: PEAD-RP35/50/60/71/100/125/140JA and JA(L) ducted indoor units (220-240 V models)

Common causes of please wait stays on, or an error shows about 2 minutes after power-up

  • Outdoor unit protection device connector not plugged in
  • Reversed or missing phase on the outdoor power terminal block (3-phase units)
  • S1-S2-S3 polarity wrong between indoor and outdoor
  • Remote controller wire shorted

How to fix please wait stays on, or an error shows about 2 minutes after power-up: step by step

  1. Wait 2 minutes after power-up before testing (and about 30 seconds after leaving function settings).
  2. Check the outdoor board LEDs: LED1 and LED2 blinking together after 2 minutes means a wiring or protection fault.
  3. Check the protection device connector on the outdoor board.
  4. Check the S1-S2-S3 wiring matches terminal for terminal.
  5. Check the remote controller wire for a short.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Mitsubishi Heat Pump codes

Models

PEAD-RP35JAPEAD-RP35JALPEAD-RP50JAPEAD-RP50JALPEAD-RP60JAPEAD-RP60JALPEAD-RP71JAPEAD-RP71JALPEAD-RP100JAPEAD-RP100JALPEAD-RP125JAPEAD-RP125JALPEAD-RP140JAPEAD-RP140JAL

Source: Mitsubishi Electric PEAD-RP35-140JA(L) Service Manual, 10-2 Self-check function, p.27-29. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977