No heat - R-32 GLZS/ALZS heat pump on a Goodman heat pump: Heat pump does not deliver heat in heating mode.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: R-32 GLZS4/5 and ALZS4/5 heat pumps

Common causes of no heat - r-32 glzs/alzs heat pump

  • Thermostat left in cool mode or wiring fault
  • Supply or transformer problem
  • Contactor, capacitor or compressor fault
  • Reversing valve stuck, mis-piped or getting 24 V on O in heat
  • Metering device fault
  • Indoor blower fault
  • Wrong charge

How to fix no heat - r-32 glzs/alzs heat pump: step by step

  1. Confirm the thermostat is in heat mode.
  2. Check 230 V to the unit and transformer, 24 V on Y and at the contactor coil (check pressure switches if missing).
  3. Contactor closed but compressor off: check wiring, run capacitor, overload and windings; let a hot compressor cool before retesting.
  4. Compressor runs but no heat: if the reversing valve is stuck between heat and cool, replace it; check for 24 V on O (it should not be energized in heat on legacy wiring).
  5. Check the reversing valve is piped correctly and the metering device works.
  6. Indoor blower off: check 24 V on G, the blower relay/control wiring and the motor.
  7. Confirm charge with subcooling and superheat.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Goodman Heat Pump codes

Models

Goodman/Amana R-32 GLZS/ALZS

ALZS4BA**10AAALZS4NA**10AAALZS5BA**10AAGLZS4BA**10AAGLZS4MA**10AAGLZS5BA**10AA

Goodman/Amana R-410A GSZ/ASZ/DSZ (ANZ/SSZ/VSZ)

ANZ130181ANZ130241ANZ130301ANZ130361ANZ130421ANZ130481ANZ130601ANZ140181ANZ140241ANZ140301ANZ140361ANZ140421ANZ140481ANZ140491ANZ140601ASZ130181ASZ130241ASZ130301ASZ130361ASZ130421ASZ130481ASZ130601ASZ140181ASZ140241ASZ140301ASZ140361ASZ140381ASZ140421ASZ140481ASZ140491ASZ140601ASZ160181ASZ160241ASZ160301ASZ160361ASZ160421ASZ160481ASZ160601ASZ180361ASZ180481ASZ180601ASZH5***10DSZ160241DSZ160361DSZ160481DSZ160601DSZ180361DSZ180481DSZ180601GSZ110903GSZ110904GSZ111203GSZ111204GSZ130181GSZ130191GSZ130241GSZ130251GSZ130301GSZ130311GSZ130361GSZ130363GSZ130371GSZ130421GSZ130481GSZ130483GSZ130484GSZ130601GSZ140181GSZ140241GSZ140301GSZ140361GSZ140371GSZ140421GSZ140481GSZ140491GSZ140601GSZ160181GSZ160241GSZ160301GSZ160361GSZ160421GSZ160481GSZ160601GSZH5***10SSZ140181SSZ140191SSZ140241SSZ140251SSZ140301SSZ140311SSZ140361SSZ140371SSZ140381SSZ140421SSZ140481SSZ140601SSZ160241SSZ160361SSZ160421SSZ160481SSZ160601VSZ130181VSZ130241VSZ130301VSZ130361VSZ130421VSZ130481VSZ130601VSZ140181VSZ140241VSZ140301VSZ140361VSZ140421VSZ140481VSZ140491VSZ140601

Goodman/Amana ComfortNet ASZC/GSZC/DSZC

ASZC160241ASZC160361ASZC160421ASZC160481ASZC160601ASZC180241ASZC180361ASZC180481ASZC180601DSZC160241DSZC160361DSZC160481DSZC160601DSZC180361DSZC180481DSZC180601GSZC160241GSZC160361GSZC160481GSZC160601GSZC180241GSZC180361GSZC180481GSZC180601

Source: Goodman RS6200301 R-32 GLXS/ALXS/GLZS/ALZS service (07-2024), Heat Pump - Heating flowchart p.52-53. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977