Glow Brand Boiler: General maintenance and inspection (owner check)

Updated · by Aurora Star Tech Inc.

General maintenance and inspection (owner check) on a Glow Brand boiler: These are the checks a homeowner can safely do between technician visits on a C95 or C140 combi. None of it needs tools or opening up gas parts. It is mostly looking, listening and smelling. Catching a vent problem, a leak or a pressure change early keeps small things from becoming no-heat calls in January.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: C95 & C140 Glow Combi boilers

Common causes of general maintenance and inspection (owner check)

  • Gas odor from a leak at the appliance or piping
  • Combustibles or flammable liquids stored too close to the boiler
  • Vent leaks or blocked vent screens
  • Pressure creeping up toward the relief valve rating, or temperature running too high
  • Slow water leaks in boiler or system piping

How to fix general maintenance and inspection (owner check): step by step

  1. Smell around the appliance for gas. If gas is present, follow the gas-smell procedure in the lighting instructions.
  2. Keep combustible materials, gasoline and flammable liquids away from the boiler area.
  3. Check all venting for leaks. Make sure vent screens are clean and clear, since a blocked intake or exhaust stops the burner.
  4. Watch for unusual noises or vibration, because those often point to air, a failing pump or a loose part.
  5. Check the operating temperature on the main display and the pressure on the relief valve gauge. Boiler pressure should be 5 psi below the relief valve rating. Boiler temperature should never exceed 180°F (82°C).
  6. Look for water leaks in the boiler and system piping. Report any concerns to a qualified technician.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Glow Brand Boiler codes

Source: C-300 C95-C140 Installation & Operation Manual, p. 75. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.