Glow Brand Boiler: Display normal but no heat to radiators
Display normal but no heat to radiators on a Glow Brand boiler: The display is lit and normal, but the radiators stay cold. That usually means the boiler is not being asked to heat, or it is waiting on a setpoint or a priority, not that something has failed. Work through the display symbols and the parameters in order.
Applies to: C95, C140 (NG and LP)
Common causes of display normal but no heat to radiators
- No heat call from the thermostat or a thermostat wiring problem
- Outdoor temperature above the warm weather shutdown setting
- Supply temperature at or above the CH setpoint minus differential, so the boiler is waiting
- CH pump not running or not wired to terminals 7 and 8
- DHW call has priority and is holding off space heating
How to fix display normal but no heat to radiators: step by step
- Look for the radiator symbol flashing during a thermostat call. If unsure, briefly short the thermostat terminals at the boiler with a jumper wire to see if the call registers, and remove it right after. Do not leave it in.
- If the symbol does not show, read outdoor temperature (1.004) and compare to warm weather shutdown (2.025), because there is no heat call above that.
- If flashing but not firing, compare supply temperature to CH setpoint (0.003). The boiler waits until supply drops below setpoint minus differential. Raise setpoint at 2.003 if too low.
- Make sure the CH pump runs and is wired to terminals 7 and 8, and measure voltage at the pump during a call.
- Radiator symbol steady and faucet symbol flashing means a DHW call has priority. Raise DHW setpoint (2.048) or shorten DHW priority time (2.043).
- Check zone valves and flow by feeling the supply and return pipes for heat.
If the unit shows an error code, look it up: Glow Brand Boiler codes
Source: Glow Brand C95 & C140 Installation & Operation Manual V.01282025 , Sec. 13.2 p.72. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.