Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Glow Brand Boiler: Display normal but no domestic hot water

Updated · by Aurora Star Tech Inc.

Display normal but no domestic hot water on a Glow Brand boiler: Heating works or display is fine but there is no hot water.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: C95, C140 (NG and LP)

How to fix display normal but no domestic hot water: step by step

  1. No tank: DHW mode (2.035) must be 5. Check DHW flow (1.062). The burner needs more than 0.5 gpm (1.9 l/m) to start. If flow is low, check supply, the cold inlet filter screen and the flow sensor wiring; replace the flow sensor if needed.
  2. Compare DHW setpoint (0.048) with DHW temperature (1.002). Burner fires when temperature is under setpoint with flow. Suggested setpoint 125 F (52 C); raise at 2.048.
  3. Tank with sensor: mode 1, sensor wired per Fig. 11.12, tank setpoint at 2.115 (default 140 F, demand starts 9 F below).
  4. Tank with aquastat: mode 2 unless using the alternate connection, aquastat wired per Fig. 11.12, max tank setpoint 135 F.
  5. If the radiator symbol flashes, DHW priority time may have run out. Cycle power and raise 2.043 or the tank setpoint.
  6. If the faucet symbol flashes with a tank, check the DHW circulator on terminals 9 and 10.
  7. Check plumbing matches Fig. 6.3 or 6.5.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Glow Brand Boiler codes

Source: Glow Brand C95 & C140 Installation & Operation Manual V.01282025 , Sec. 13.2 p.73. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977