Glow Brand Boiler: Display normal but hot water not hot enough
Display normal but hot water not hot enough on a Glow Brand boiler: Glow Brand C95/C140 shows normal on the display but the hot water is not hot enough. Usually it's a setpoint thing or the mixing valve. Scald risk is real above 120 F, so don't just crank it up.
Applies to: C95, C140 (NG and LP)
Common causes of display normal but hot water not hot enough
- DHW setpoint set too low for the type of tank
- Thermostatic mixing valve set low or not working correctly
How to fix display normal but hot water not hot enough: step by step
- Raise the DHW setpoint: about 120 F with no tank, 120 to 140 F with a sensor tank (mode 1), 120 to 130 F with an aquastat tank (mode 2).
- Check the thermostatic mixing valve. Any setting over 120 F needs one installed.
- Confirm which mode the boiler is set for before changing the setpoint.
- Check delivered temperature at the tap with a thermometer, not by hand.
- Explain the scald risk to the homeowner after any increase.
If the unit shows an error code, look it up: Glow Brand Boiler codes
Source: Glow Brand C95 & C140 Installation & Operation Manual V.01282025 , Sec. 13.2 p.74. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.