Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Glow Brand Boiler: Display normal but DHW not hot enough

Updated · by Aurora Star Tech Inc.

Display normal but DHW not hot enough on a Glow Brand boiler: Display normal, hot water runs, but it comes out lukewarm at the tap. Usually a setting, sometimes the mixing valve.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: C95 & C140 Glow Combi boilers

Common causes of display normal but dhw not hot enough

  • DHW setpoint set too low for the DHW mode
  • Faulty or misadjusted thermostatic mixing valve
  • Mixing valve set to blend in too much cold water

How to fix display normal but dhw not hot enough: step by step

  1. Raise the DHW setpoint to the recommended value for the DHW mode (see the DHW setpoint table in this section).
  2. Check the thermostatic mixing valve for proper operation.
  3. Measure tap temperature with a thermometer after a minute of flow.
  4. Any DHW setting above 120°F requires a thermostatic mixing valve, so do not raise it without one because of scald risk.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Glow Brand Boiler codes

Source: C-300 C95-C140 Installation & Operation Manual, p. 74. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977