Glow Brand Boiler: Clear a lockout
Clear a lockout on a Glow Brand boiler: Hard lockouts (Loc) are not cleared by cycling power.
Applies to: B85, B120, B160 (NG and LP)
How to fix clear a lockout: step by step
- Hold RESET/ENTER for at least 2 seconds on the display.
- For software lockouts also press the small reset button on the back of the ICB.
- Too many resets in a row triggers Err 134; then cycle power and fix the real cause.
If the unit shows an error code, look it up: Glow Brand Boiler codes
Models
Source: Glow Brand B85/B120/B160 Installation & Operation Manual V20231025, 12.1 p.61; 12.2 p.65. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.