Daikin Water Heater: Mount the tank control board and water temperature sensors
Mount the tank control board and water temperature sensors on a Daikin water heater: Controller kit is mounted on a field-supplied hot water storage tank. Sensors are placed at lower (1), middle (2) and upper (3) positions.
Applies to: Controller kit BRP26B2VJU
How to fix mount the tank control board and water temperature sensors: step by step
- Secure the controller kit onto the field hot water storage tank.
- Install the bracket for the control board with 4 bolts, nuts and flat washers (M12).
- Wrap sealing tape around the thread of each water temperature sensor.
- Screw each sensor into its socket inside the tank (sensors 1 lower, 2 middle, 3 upper).
- Secure the storage box with 4 screws (M4 x 8).
- Secure the storage box cover with 2 self-tapping screws (M4 x 8).
- Handle the sensors carefully because they are precision instruments. Replace any that are dropped or shocked.
If the unit shows an error code, look it up: Daikin Water Heater codes
Source: Daikin Mega-Q installation manual, p. 56. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.