Daikin Water Heater: Connect water temperature sensors to tank control board
Connect water temperature sensors to tank control board on a Daikin water heater: Connect the three relay wire harnesses (accessory) to the tank control board. Match each harness to its board connector by color, and check the harness is at the correct sensor position.
Applies to: Mega-Q hot water generation system, tank control board
How to fix connect water temperature sensors to tank control board: step by step
- Connect relay harness for sensor 1 (R1T, white, X13A) to the board.
- Connect relay harness for sensor 2 (R2T, yellow, X17A) to the board.
- Connect relay harness for sensor 3 (R3T, red, X18A) to the board.
- Pass the relay harnesses through the wire clips on the board.
- Secure the harness clamp (accessory) so no external force reaches the connectors.
- When closing the tank control board cover, make sure no wiring is pinched.
If the unit shows an error code, look it up: Daikin Water Heater codes
More commissioning tips for water heater
Source: Daikin Mega-Q installation manual, p. 64 of 68. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.