Daikin Mini-Split: 2-Area INTELLIGENT EYE detection and energy saving

Updated · by Aurora Star Tech Inc.

2-Area INTELLIGENT EYE detection and energy saving on a Daikin mini-split: Applies to FTXM09/12WVJU9 and FTXM09/12VVJU. The motion sensor splits the room into 2 areas. If no one is present, capacity is reduced to save power. If people are present in an area, the airflow direction is moved to the area with no one, to avoid blowing directly on occupants.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: FTXM09/12WVJU9, FTXM09/12VVJU

How to fix 2-area intelligent eye detection and energy saving: step by step

  1. The indoor unit microcomputer samples the motion sensor every 20 msec.
  2. Human presence is judged when the sensor reports 10 or more pulses in one second and the High signal lasts 2 seconds.
  3. No detected presence: reduce capacity for energy saving.
  4. Presence in one area: move airflow to the area with no people.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Mini-Split codes

Source: SiUS042113EA service manual, p. 48. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.