Daikin Heat Pump: Unit runs but does not cool or heat

Updated · by Aurora Star Tech Inc.

Unit runs but does not cool or heat on a Daikin heat pump: System runs but gives no useful heating or cooling effect.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: FTXM-W/V wall mounted indoor and outdoor units

Common causes of unit runs but does not cool or heat

  • Wiring or piping errors between indoor and outdoor units
  • Faulty thermistor or loose thermistor mounting
  • Electronic expansion valve not working
  • Refrigerant shortage

How to fix unit runs but does not cool or heat: step by step

  1. Check wiring and piping between indoor and outdoor units for errors.
  2. Check that each thermistor is mounted securely.
  3. Set the unit to cooling and check the liquid pipe temperature to confirm the electronic expansion valve is working.
  4. Read the error code on the remote controller (p. 96).
  5. Check service port pressure and operating current to look for refrigerant shortage.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Heat Pump codes

Source: Daikin FTXM-W/V service manual SiUS042113EA, p. 96. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.