Daikin Heat Pump: Unit operates but does not cool or does not heat
Unit operates but does not cool or does not heat on a Daikin heat pump: The unit runs but gives no cooling or heating. Check wiring and piping, sensors, the expansion valve and refrigerant charge.
Applies to: FTXM-W/V wall mounted inverter pair
Common causes of unit operates but does not cool or does not heat
- Wiring or piping errors between indoor and outdoor units
- Thermistor detection error or loose thermistor
- Faulty electronic expansion valve operation
- Refrigerant shortage
How to fix unit operates but does not cool or does not heat: step by step
- Check the wiring and piping between the indoor and outdoor units for errors.
- Check that each thermistor is mounted securely.
- Set the unit to cooling and check the liquid pipe temperature to see whether the electronic expansion valve works.
- Diagnose using the remote controller indication (see p. 96).
- Check service port pressure and operating current to look for refrigerant shortage.
If the unit shows an error code, look it up: Daikin Heat Pump codes
Source: SiUS042113EA service manual, p. 96. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.