Daikin Heat Pump: Unit does not operate
Unit does not operate on a Daikin heat pump: The unit does not start. Work through the power, unit type, outdoor temperature, remote diagnosis and remote address checks in order.
Applies to: FTXM-W/V wall mounted inverter pair
Common causes of unit does not operate
- No or wrong supply voltage
- Indoor unit type not compatible with outdoor unit
- Outdoor temperature outside the operation limit
- Remote controller addresses not set correctly
How to fix unit does not operate: step by step
- Check the power supply and confirm the rated voltage is present.
- Confirm the indoor unit type is compatible with the outdoor unit.
- Check the outdoor temperature against the operation limit on the reference page (p. 176).
- Diagnose using the remote controller indication (see p. 96).
- Check that the remote controller and indoor unit addresses are set correctly (see p. 159).
If the unit shows an error code, look it up: Daikin Heat Pump codes
Source: SiUS042113EA service manual, p. 96. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.