Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Heat Pump: Removing pinch piping from the heat source unit

Updated · by Aurora Star Tech Inc.

Removing pinch piping from the heat source unit on a Daikin heat pump: Pinch piping must be vented before it is removed, otherwise the stop valve can rupture or residual oil can catch fire.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Heat source unit stop valve connections

How to fix removing pinch piping from the heat source unit: step by step

  1. Remove the valve cover and check that the stop valve is fully closed.
  2. Connect a charge hose with push rod to the service port and check for no residual pressure.
  3. Cut the small pinch piping with a piping cutter so a cross section opens. Confirm again there is no residual pressure.
  4. Leave the pipe until the oil runs out.
  5. Remove the large pinch piping.
  6. Drain all gas and oil from the pinch piping before removing it.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Heat Pump codes

Source: Daikin Mega-Q installation manual, p. 18. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service