Daikin Heat Pump: Remove the solenoid valve, four way valve and EEV coils
Remove the solenoid valve, four way valve and EEV coils on a Daikin heat pump: Removal of the coil leads from the valves on 3.5 to 5.0 ton HP models.
Applies to: 3.5 to 5.0 ton HP models
How to fix remove the solenoid valve, four way valve and eev coils: step by step
- Cut the 2 clamps on the solenoid valve coil lead wire.
- Remove the 2 M4 screws and take off the solenoid valve coil.
- Remove the 1 M5 screw and take off the four way valve coil.
- Cut the clamp and pull out the electronic expansion valve coil.
- On reassembly, torque the solenoid coil screws to 1.47-1.96 N·m and the four way coil screw to 3.2±0.8 N·m.
If the unit shows an error code, look it up: Daikin Heat Pump codes
Source: Daikin SiUS612209EA service instructions, p. 112. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.