Remove partition plate and outer sound blanket (heat pump, 1.5 to 3.0 ton) on a Daikin heat pump: Start of the compressor access sequence for heat pump models. The sequence continues on the following pages.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DX6VS / DZ6VS heat pump outdoor units, 1.5 to 3.0 ton

How to fix remove partition plate and outer sound blanket (heat pump, 1.5 to 3.0 ton): step by step

  1. Remove the 2 screws and take off the partition plate. The upper screw is a truss head tapping screw or hex head screw (M4 x 12). On reassembly, insert the bottom frame hook into the slit of the partition plate.
  2. Remove the sound blanket (outer top).
  3. On reassembly, insert all of the outer top blanket edge into the outer body blanket. Make sure the outer top blanket does not stand above the outer body blanket.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Heat Pump codes

Source: Daikin DX6VS/DZ6VS service instructions SiUS612209EB, p. 96. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.