Daikin Heat Pump: Remove compressor – heat pump models, 3.5 to 5.0 ton
Remove compressor - heat pump models, 3.5 to 5.0 ton on a Daikin heat pump: Removal and reinstall steps for the compressor on heat pump outdoor units. Shown on the step 6-7 pages only; steps 1-5 are not on these pages.
Applies to: 3.5 to 5.0 ton heat pump outdoor units
How to fix remove compressor - heat pump models, 3.5 to 5.0 ton: step by step
- Remove the overload (OL) device. When refitting, hook the lower tabs of the retainer into the square holes of the fixture first, then push the upper hooks until they latch in the square holes. Route the OL lead wire and harness as shown.
- Before any brazing, remove putty, the terminal cover and other plastic parts that could burn. Put a protective sheet or steel plate under the work so the flame does not reach nearby parts.
- Heat the brazed joints of the compressor piping and disconnect them. Keep the piping strain within the angle shown in the manual.
- Remove the 2 nuts that hold the compressor to the base. The nut and brazed-part locations differ between 3.5/4.0 ton and 5.0 ton units.
If the unit shows an error code, look it up: Daikin Heat Pump codes
Source: Daikin DX6VS/DZ6VS service instructions SiUS612209EB, p. 120. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.