Daikin Heat Pump: Refrigerant system and discharge thermistor check (Check 14)
Refrigerant system and discharge thermistor check (Check 14) on a Daikin heat pump: Checks for refrigerant loss and that the discharge pipe thermistor is seated in its holder.
Applies to: Refrigerant circuit and discharge pipe thermistor
Common causes of refrigerant system and discharge thermistor check (check 14)
- Refrigerant leak or shortage
- Discharge pipe thermistor came off its holder
How to fix refrigerant system and discharge thermistor check (check 14): step by step
- Check the refrigerant system for leakage.
- If there is a leak or shortage, follow the refrigerant shortage diagnosis (U0).
- Check whether the discharge pipe thermistor has come off its holder.
- If it is off the holder, reattach it.
- Replace the refrigerant if the system check requires it.
If the unit shows an error code, look it up: Daikin Heat Pump codes
Source: Daikin Inverter Pair FTXM-W/V service manual SiUS042113EA, p. 150. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.