Daikin Heat Pump: Outdoor fan motor check (Check No.16)

Updated · by Aurora Star Tech Inc.

Outdoor fan motor check (Check No.16) on a Daikin heat pump: Checks the outdoor fan motor and its control signals. The 09/12 class and 18/24 class use different test points.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Outdoor unit fan motor, 09/12 and 18/24 class

How to fix outdoor fan motor check (check no.16): step by step

  1. 09/12 class: with power off, rotate the fan motor by hand once and check for a sinusoidal voltage between pins 1-3 and 3-5.
  2. 18/24 class: set operation OFF and power OFF, then disconnect connector S70.
  3. 18/24 class: check for 320 VDC between pins 4-7 (should be 320 VDC).
  4. 18/24 class: check for 15 VDC control voltage between pins 3-4.
  5. 18/24 class: check for a rotation command of 0 to 6.5 VDC between pins 2-4.
  6. Keep operation OFF and power OFF, then reconnect S70.
  7. 18/24 class: rotate the fan motor one turn by hand and check for 4 pulses (0 to 15 VDC) at pins 1-4.
  8. If the fuse has blown, check the fan motor for proper function.
  9. If step 2 (320 VDC) is NG, replace the outdoor unit PCB (main PCB).
  10. If step 4 (rotation command) is NG, the Hall IC is defective: replace the outdoor fan motor.
  11. If both steps 2 and 4 are OK, replace the outdoor unit PCB (main PCB).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Heat Pump codes

Source: Daikin Inverter Pair FTXM-W/V service manual, p. 152. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.