Updated · by Aurora Star Tech Inc.

Outdoor coil thermistors used for defrost on a Daikin heat pump: The control board uses two outdoor thermistors for defrost: the outdoor coil thermistor (Tm) on the return bend entering the coil, and the outdoor coil defrost thermistor (Tb) at the bottom flowrator leg at the coil outlet.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Outdoor heat pump coils

How to fix outdoor coil thermistors used for defrost: step by step

  1. Locate Tm on the return bend entering the outdoor coil.
  2. Locate Tb on the bottom flowrator leg at the coil outlet.
  3. Check the readings against the thermistor resistance tables in this manual when diagnosing defrost problems.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Heat Pump codes

Source: Daikin DX6VS/DZ6VS service instructions SiUS612209EA, p. 7. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.