Daikin Heat Pump: Operation sometimes stops
Operation sometimes stops on a Daikin heat pump: The unit stops intermittently. Check for power interruptions and outdoor temperature limits, then diagnose from the remote.
Applies to: FTXM-W/V wall mounted inverter pair
Common causes of operation sometimes stops
- Short power failure (2 to 10 cycles) stops operation
- Outdoor temperature outside the operation limit
How to fix operation sometimes stops: step by step
- Check the power supply for short interruptions; a power failure of 2 to 10 cycles stops operation and the operation lamp goes off.
- Check the outdoor temperature against the operation limit (p. 176).
- Diagnose using the remote controller indication (see p. 96).
If the unit shows an error code, look it up: Daikin Heat Pump codes
Source: SiUS042113EA service manual, p. 96. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.