Daikin Heat Pump: Interpret target vs actual discharge temperature

Updated · by Aurora Star Tech Inc.

Interpret target vs actual discharge temperature on a Daikin heat pump: Compare the target discharge temperature with the actual discharge temperature in D-Checker to judge the refrigerant charge.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Daikin inverter heat pump outdoor units

Common causes of interpret target vs actual discharge temperature

  • Target discharge temperature higher than actual can mean an overcharge.
  • Actual discharge temperature higher than target can mean an undercharged system.

How to fix interpret target vs actual discharge temperature: step by step

  1. Wait for D-Checker to calculate the target discharge temperature (up to about 20 minutes).
  2. Compare target and actual discharge temperature.
  3. If target is higher than actual, check for an overcharge.
  4. If actual is higher than target, check for an undercharge.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Heat Pump codes

Source: Daikin SiUS612209EB service instructions, p. 134. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.