Daikin Heat Pump: Checking the outdoor or indoor pressure sensor

Updated · by Aurora Star Tech Inc.

Checking the outdoor or indoor pressure sensor on a Daikin heat pump: The pressure sensor reads low or high side pressure and outputs a DC voltage that rises with pressure. Output range shown is 0 to 4 VDC for 0 to 800 PSIG.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Outdoor unit (1.5–5.0 ton) and indoor unit pressure sensors

Common causes of checking the outdoor or indoor pressure sensor

  • Open or shorted sensor
  • Voltage outside the valid range

How to fix checking the outdoor or indoor pressure sensor: step by step

  1. With power on, connect a voltmeter across the sensor terminals between the black and white wires.
  2. Compare the reading with the voltage vs. pressure characteristic for the unit (1.5–3.0 ton outdoor, or 3.5–5.0 ton outdoor and indoor).
  3. Replace the sensor if it is open, shorted, or outside the valid voltage range.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Heat Pump codes

Source: Daikin DX6VS/DZ6VS service instructions SiUS612209EB, p. 17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.