Daikin Heat Pump: Checking the high pressure switch
Checking the high pressure switch on a Daikin heat pump: The high pressure switch opens the control circuit on abnormally high discharge pressure, before the compressor overloads. It does not reset automatically.
Applies to: High pressure switch on the outdoor unit control circuit
Common causes of checking the high pressure switch
- Open switch contacts
- Broken or loose wiring at the PCB connection
How to fix checking the high pressure switch: step by step
- Disconnect power and wait for the high voltage to be cleared.
- Remove the wire on the PCB side of the switch.
- Use an ohmmeter across the PCB-side switch terminals.
- If the reading is not continuous, the circuit is open. Replace the switch if necessary.
- After a trip, turn main power off to reset the switch.
If the unit shows an error code, look it up: Daikin Heat Pump codes
Source: Daikin DX6VS/DZ6VS service instructions SiUS612209EB, p. 16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.