Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Heat Pump: Check compressor efficiency (S-104)

Updated · by Aurora Star Tech Inc.

Check compressor efficiency (S-104) on a Daikin heat pump: Low compressor efficiency means the compressor cannot pump vapor well. Confirm the charge is correct before condemning the compressor.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Outdoor units DX6VS / DZ6VS

Common causes of check compressor efficiency (s-104)

  • Broken or damaged compressor
  • Incorrect refrigerant charge (check first)

How to fix check compressor efficiency (s-104): step by step

  1. Attach gauges to the high and low side of the system.
  2. Start the system and run CHARGE MODE.
  3. If the charge is correct and the readings show low high-side pressure, high low-side pressure, low temperature difference across the coil, and low compressor amp draw, the compressor is faulty. Replace it.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Heat Pump codes

Source: Daikin SiUS612209EA service instructions, p. 22. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.