Daikin Heat Pump: Aux relay wiring to a field device
Aux relay wiring to a field device on a Daikin heat pump: Wire an aux output so the thermostat closes a dry contact to start the field equipment.
Applies to: Aux 1 / Aux 2 outputs on the Daikin One Touch thermostat
How to fix aux relay wiring to a field device: step by step
- Use at least 18 AWG wire and keep the run to 125 ft or less.
- Pick an aux terminal pair (Aux 1 or Aux 2) and note it for the installer wizard.
- Wire the field device to the N.O. and Com of the SPST relay side, with line voltage on the field device side.
- Route the 24 VAC control signal through one of the aux contacts.
- Set the aux terminal in the Daikin One installer wizard.
- Check that the field device energizes when the aux output is called.
If the unit shows an error code, look it up: Daikin Heat Pump codes
Source: Daikin One Touch Smart Thermostat training module TRC-10, p. 16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.